❄ Compressor Code Lookup
Home › Gardner Denver › ADVISORY #301 CHANGE SEPARATOR
Gardner Denver AirSmart controller · ADVISORY #301 CHANGE SEPARATOR

What does Gardner Denver advisory 301 change separator mean?

Short answer: Separator element pressure drop warning. If your Gardner Denver AirSmart controller is showing ADVISORY #301 CHANGE SEPARATOR, the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

Differential pressure across the separator element exceeded 8 PSIG — the element is loading up and should be changed before it forces a shutdown at 15 PSIG.

Which machines show this?

Gardner Denver rotary screw compressors fitted with the first-generation AirSmart microprocessor controller — a wide range of oil-injected packages, including VFD-equipped variable-speed units where the controller supervises the drive. The first-generation AirSmart reports problems as numbered codes: SHUTDOWN #1xx and #2xx faults that stop the machine, and ADVISORY #3xx warnings that let it keep running while flagging maintenance. That numbering matters when you search — the later AirSmart G2 dropped the numbers and displays plain-text fault names instead, so a numbered code on the screen tells you that you are on the earlier controller. Shutdowns clear with Stop/Reset once the machine has stopped; advisories acknowledge with the Enter key.

What causes it?

  • Separator element pressure drop passed the 8 PSIG warning threshold — the element is loading up
  • Normal element life reached; it will keep plugging until the 15 PSIG shutdown at #202

Can you fix it yourself?

The advisory itself is just an acknowledgment away — but the real fix is ordering the correct Gardner Denver element now and scheduling the change before the machine forces the issue with a shutdown.

Step by step — what to try, in order:

  1. Order the correct Gardner Denver separator element for your model
  2. Schedule replacement before the 15 PSIG shutdown threshold is reached
  3. Press Enter on the controller to acknowledge the advisory
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

The element lives inside the pressurized air/oil separator tank, which has to be fully depressurized before opening — that's why the swap is a technician visit, not a filter change.

When to call: Have a technician replace the element — the separator tank must be depressurized before opening.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does ADVISORY #301 CHANGE SEPARATOR mean on a Gardner Denver AirSmart controller?

Separator element pressure drop warning. Differential pressure across the separator element exceeded 8 PSIG — the element is loading up and should be changed before it forces a shutdown at 15 PSIG.

Can I fix ADVISORY #301 CHANGE SEPARATOR on a Gardner Denver AirSmart controller myself?

The advisory itself is just an acknowledgment away — but the real fix is ordering the correct Gardner Denver element now and scheduling the change before the machine forces the issue with a shutdown.

When does ADVISORY #301 CHANGE SEPARATOR on a Gardner Denver AirSmart controller need a technician?

The element lives inside the pressurized air/oil separator tank, which has to be fully depressurized before opening — that's why the swap is a technician visit, not a filter change. Have a technician replace the element — the separator tank must be depressurized before opening.

Verified against service documentation: Gardner Denver AirSmart controller documentation for ADVISORY #301 CHANGE SEPARATOR (best-aire.com)

Other Gardner Denver AirSmart controller codes