Air compressor tripped on a fault code?

176 documented fault codes across Atlas Copco, Gardner Denver, Ingersoll Rand, Kaeser, Quincy, and Sullair, verified against service manuals — what each one means, what to check yourself, and when it's a tech call.

Most-searched Kaeser fault codes

People looking up a Kaeser fault code, a fault code list, or fault code 2 usually land here first. These are Sigma Control 2 pages already on this site. The full Kaeser fault code list covers Sigma Control 2 and the original Sigma Control.

  • Kaeser 0001 A — motor turning the wrong direction.
  • Kaeser 0002 A — compressor motor too hot; the controller shut the machine down.
  • Kaeser 0002 W — compressor motor running hot, still a warning.
  • Kaeser 0004 A — the emergency stop button was pressed.
  • Kaeser 0005 A — air temperature at the oil separator tank outlet was too high.
  • Kaeser 0008 W — airend discharge temperature is approaching the shutdown limit.
  • Kaeser 0012 A — a maintenance door or cover panel was open while the machine was running.
  • Kaeser 0013 A — compressor motor overcurrent shutdown.
  • Kaeser 0013 W — intake air filter is clogged; change the air filter.
  • Kaeser 0015 A — airend discharge temperature went past the maximum the controller allows.

Find your controller

Every code on this site is filed by brand and by the controller that displays it, because the same fault can read differently from one controller to the next. Match the name on your display or in your manual:

  • Atlas Copco - Elektronikon controllers (Elektronikon II regulator, Mk 5, Touch and Graphic) on GA and GA VSD machines.
  • Gardner Denver - AirSmart and AirSmart G2 controllers.
  • Ingersoll Rand - Intellisys on SSR machines, and Xe-series controllers.
  • Kaeser - Sigma Control and Sigma Control 2.
  • Quincy - QSI standard controls, INFOLOGIC and Airlogic2.
  • Sullair - Sullair Touch Screen (STS), WS, Supervisor and ShopTek controllers.

Warning or shutdown?

Most controllers sort their messages into two levels. A warning (Kaeser marks these with a W; Gardner Denver calls them advisories) means the machine is still running but a limit is getting close: a filter loading up, a temperature climbing, a service interval coming due. A shutdown or alarm (Kaeser marks these with an A) means the controller has already stopped the compressor to protect it. A warning is your chance to fix a small problem cheaply. A shutdown needs its cause found before you restart.

Either way, write down the exact code and message before you reset anything. One reset is diagnosis; if the same fault comes back, the condition behind it is real, and the code page will tell you what to check yourself and when it is time for a technician.

Start with these high-intent codes

These shutdown messages are the ones people look up first. Each link goes to a page that already says what the controller measured, which checks are operator work, and where it becomes a technician's job.

Frequently asked questions

Where do I read the code on an Elektronikon, and where on a Sigma Control?

On an Elektronikon II the message is usually not a bare number. The display names the sensor, shows the live reading, and puts Shd or Shdw beside the programmed limit. A Mk 5 shows the shutdown as an on-screen message with the measured value and the programmed level. On a Sigma Control 2 the code is a four-digit number plus a letter on the text display, such as 0015 A. On the original Sigma Control it is a short message with (A) or (W), such as ADT (A). Write down the whole line, letter or tag included, before you reset. The Atlas Copco list and the Kaeser list are filed by which controller is on the machine.

On a Kaeser, how do I read W versus A when the number looks the same?

W means the machine is still running. A means the controller has shut it down. The same four digits can exist with both letters and mean different things: 0013 W is a clogged intake air filter, and 0013 A is a motor-overcurrent shutdown. Temperature uses two numbers. 0008 W is the airend-discharge warning while the compressor keeps running, and 0015 A is the shutdown after the maximum temperature was exceeded. Read the letter before you search only the digits.

Is an Atlas Copco F-code the same kind of message as Element Outlet Shd?

No. An F-code on a GA VSD with an integrated drive is the drive reporting the fault. F020 is excessive current to the motor. A compressor-side shutdown such as Element Outlet Shd is the Elektronikon naming a sensor and a temperature limit. If the screen shows F020, use the F020 page. If it shows Element Outlet and Shd, use the element-outlet shutdown page.

Local service

Guides

Equipment still down? If you're in Middle Tennessee or Central Alabama, see who services industrial air compressors near you: