32 documented codes and fault messages across 2 controller families, each verified against Kaeser service documentation, with the meaning, the operator checks, and when it takes a technician.

Home › Kaeser

Kaeser rotary screw compressors are run by Sigma Control, and the fault language depends on the generation. First-generation Sigma Control, the green-keypad text-display unit on the AS, BS, CS, DS, ES and SK/SM/SX series from around 2000, shows short lower-case messages with a severity letter: ADT (A) for an airend discharge temperature trip, motor T (A) for a hot drive motor, separator dp (W) for a clogging separator. Sigma Control 2, the industrial-PC controller with RFID access on ASD, BSD, CSD, DSD, ESD and related machines built since about 2011, uses a four-digit number plus a letter, with arrows marking whether the value went over or under its limit.

How to read the display. The letter is the severity. A is an alarm: the controller has shut the machine down to protect it, and it stays down until the cause is fixed and the message is acknowledged with the reset key. W is a warning or service reminder the machine keeps running through. The number alone is not enough, because the same number can exist with both letters and mean different things: 0013 A is a motor overcurrent shutdown, 0013 W means change the air filter. The same subsystem often has a W code that comes before its A code, so 0004 W (oil separator differential pressure rising) is your early notice of 0022 A (oil separator clogged, shutdown), and 0008 W (airend temperature approaching the limit) is the warning before 0015 A, the overheat trip. Two quirks are worth knowing: the message numbers are not consecutive, and the exact set varies with how the machine is equipped, so a number you have never seen is an option your machine has that another does not. Original Sigma Control machines also enforce a minimum start temperature of +3 °C, so a winter no-start in an unheated room is often the controller doing its job.

What is safe to do yourself. Kaeser's manuals are unusually explicit about which remedies belong to operators (cleaning coolers, checking oil level after cooldown, replacing air filters) and which require the machine depressurised and a trained technician (anything inside the separator tank or the electrical cabinet). The pages below preserve that line.

The tables below list every documented message by controller generation. Each links to its own page with the meaning, the machines that show it, the likely causes, the operator checks, and the handoff point to a technician. Each page cites the Kaeser service manual it was verified against.

Five Kaeser codes to know first

  1. 0015 A — Airend discharge temperature ADT ⇞ (Kaeser Sigma Control 2): Airend discharge temperature too high (shutdown).
  2. 0013 W — Air filter Δp ↑ - Change air filter! (Kaeser Sigma Control 2): Air filter clogged.
  3. 0022 A — Oil separator Δp ⇞ (Kaeser Sigma Control 2): Oil separator cartridge clogged (shutdown).
  4. 0004 A — EMERGENCY STOP (Kaeser Sigma Control 2): Emergency stop button pressed.
  5. ADT (A) (Kaeser Sigma Control (original)): Airend discharge temperature exceeded (original Sigma Control).

Every documented Kaeser code, by controller

Find the message shown on your display. Each row links to that code's own page.

Kaeser Sigma Control (original) codes (6)

CodeMeaningPage
ADT (A)Airend discharge temperature exceeded (original Sigma Control)What to do →
motor T (A)Drive motor too hotWhat to do →
separator dp (W)Oil separator cloggedWhat to do →
no press. buildup (A)No pressure buildupWhat to do →
start T (A)Too cold to startWhat to do →
emergency stop (A)Emergency stop button pressedWhat to do →

Kaeser Sigma Control 2 codes (26)

CodeMeaningPage
0015 A — Airend discharge temperature ADT ⇞Airend discharge temperature too high (shutdown)What to do →
0008 W — Airend discharge temperature ADT ↑Airend temperature approaching shutdown limit (warning)What to do →
0017 A — Safety shutdown ADTADT safety shutdownWhat to do →
0043 A — Airend discharge temperature ADT rise dT/dt ⇞Airend temperature rising too fastWhat to do →
0002 A — Motor temperature ⇞Compressor motor too hot (shutdown)What to do →
0013 A — Compressor motor overcurrentMotor overload shutdownWhat to do →
0004 A — EMERGENCY STOPEmergency stop button pressedWhat to do →
0012 A — Access doorsAccess door open while runningWhat to do →
0022 A — Oil separator Δp ⇞Oil separator cartridge clogged (shutdown)What to do →
0004 W — Oil separator Δp ↑Oil separator differential pressure rising (warning)What to do →
0033 A — Oil pressure ⇟Oil pressure too lowWhat to do →
0039 A — PD temperature ⇞Package discharge temperature too highWhat to do →
0044 A — No pressure buildupMachine not building pressureWhat to do →
0041 A — Mains voltage ⇟Power supply failure (second occurrence)What to do →
0002 W — Motor temperature ↑Compressor motor running hot (warning)What to do →
0013 W — Air filter Δp ↑ - Change air filter!Air filter cloggedWhat to do →
0011 W — Oil filter 1 Δp ↑Oil filter cloggedWhat to do →
0025 W — Oil separator h ⇞Oil separator maintenance interval expiredWhat to do →
0026 W — Oil change h ⇞Cooling oil change dueWhat to do →
0028 W — Air filter h ⇞Air filter maintenance interval expiredWhat to do →
0036 W — Motor starts/h ⇞Too many motor starts per hourWhat to do →
0046 W — System pressure ↓Network pressure below low-pressure warning valueWhat to do →
0060 W — Start temperature ↓Machine too cold to startWhat to do →
0071 W — Oil level ↓Cooling oil level too lowWhat to do →
0005 A — Oil separator Temperature ⇞Air temperature at oil separator tank outlet too highWhat to do →
0001 A — Direction of rotationMotor turning the wrong directionWhat to do →