Sullair Air Compressor Fault Codes: Complete List with Fixes

33 documented codes and fault messages across 5 controller families, each verified against Sullair service documentation, with the meaning, the operator checks, and when it takes a technician.

Home › Sullair

Sullair machines have worn several controllers over the years, and identifying yours is step one. Current stationary machines, the LS-series and related packages from the late 2010s on, carry the 10-inch Sullair Touch Screen (STS). The WS controller, a text-display unit on mid-range shop and light-industrial packages from the 2010s, and the older Supervisor on large-frame industrial machines ran the generations before it. On variable-speed Supervisor-era packages the Supervisor also relays numbered faults from the drive itself (Drive Fault 14, Drive Fault 9, VSD Code 51). Smaller ShopTek ST-series machines for garages and light manufacturing use their own compact ShopTek panel.

How to read the display. Sullair's fault language is mostly plain text and consistent across controllers: HIGH DISCH TEMP, MOTOR OVERLOAD, PR XDCR FAULT, High Separator dP. The Supervisor is the exception, reporting by channel: temperatures are T1 to T5, pressures P1 to P4, differential pressure dP1, so a fault reads "T2 Discharge High" rather than a name. On every controller a warning keeps the machine running and a fault shuts it down until reset (from the STOP key on the WS, after the unit has cooled). The thresholds barely move between generations: discharge temperature warns around 225 °F and faults at 235 °F delayed or 255 °F immediate, the separator differential warns around 10 psid, and the manuals document a 105 °F ambient limit. On the STS, photograph the fault screen and the Recommended Service page before clearing anything; the service-hour counters usually point straight at the consumable that caused the trip. On the ShopTek, learn which messages are reminders (A-O SEPARATOR is a service interval, not a failure) and which are trips.

The summer pattern. That 105 °F ambient limit is the punchline of most Sullair service calls: high-temperature trips in July are usually the room and the cooler, not the machine. Cooler cleaning, ventilation and fluid level are operator checks. Sump pressure faults, drive cabinets and anything pressurised are where the right move is to stop and call. One more: if the WS auto-restart timer is configured the machine can start by itself after a Power Interruption, so make sure nobody is working near it.

The tables below list every documented fault by controller. Each links to its own page with the meaning, the machines that show it, the likely causes, what your own crew can safely check, and when to call. Each page cites the Sullair manual it was verified against.

Five Sullair codes to know first

  1. High Temperature 1 / 2 / 3 (Sullair Touch Screen (STS)): High compressor temperature trip.
  2. High Separator dP (Sullair Touch Screen (STS)): High pressure drop across air/fluid separator.
  3. Main Motor Overload (Sullair Touch Screen (STS)): Main drive motor overload trip.
  4. HIGH DISCH TEMP (Sullair ShopTek Controller): High discharge temperature warning/trip.
  5. Drive Fault 14 (Over-temperature) (Sullair Supervisor Controller (VSD drive faults)): VSD heatsink over-temperature.

Frequently asked questions

How do I tell which Sullair controller I have, and how do the codes appear?

Current stationary machines, the LS-series and related packages from the late 2010s on, carry the 10-inch Sullair Touch Screen (STS). Faults are plain text. High Temperature 1 / 2 / 3, High Separator dP, and Main Motor Overload are three of those messages. Photograph the fault screen and the Recommended Service page before you clear anything. The WS controller is the text display on mid-range shop and light-industrial packages from the 2010s. A temperature trip there reads High Temperature 1-3, and you reset it from the STOP key after the unit has cooled. Smaller ShopTek ST-series machines use a compact panel and short text such as HIGH DISCH TEMP. A-O SEPARATOR on that panel is a service-interval reminder, not a failure. The older Supervisor on large-frame machines reports by channel, temperatures T1 to T5 and pressures P1 to P4, so a fault reads T2 Discharge High rather than a name. On a variable-speed Supervisor package the same controller also relays numbered faults from the drive: Drive Fault 14, Drive Fault 9, and VSD Code 51.

What does High Temperature 1 / 2 / 3 mean, and what should I check?

On the STS, High Temperature 1 / 2 / 3 means the temperature at the indicated probe exceeded the set high limit and the controller shut the compressor down. Sullair lists high ambient above 105°F (41°C), low fluid level, a stuck thermal valve, dirty cooler fins, or a failed temperature probe. If the room is above 105°F (41°C), improve the ventilation. With the unit stopped and cooled, check the fluid level and clean the cooler fins and fan blades. On a water-cooled unit, confirm the cooling-water valves are open and the pump is running. After cooldown, press Stop to reset and restart while watching the temperature. If it trips again after the cooler is clean and the fluid level is right, the thermal valve or the temperature probe needs a technician. ShopTek HIGH DISCH TEMP is the same kind of trip on the smaller panel: a warning when discharge temperature exceeds 225°F (107°C), and a STOP fault when the set limit is exceeded. Causes listed for that message include ambient above 105°F (40°C), low fluid, a thermal-valve fault, dirty cooler fins, or a failed temperature sensor. The WS page is the one that states trip numbers. It warns at 225°F and faults at 235°F time-delayed or 255°F immediate. Those figures belong to the WS controller. Do not paste them onto an STS screen that only says the set high limit.

What is the difference between a warning and a shutdown, and between a drive fault and a compressor fault?

A warning leaves the machine running. A fault shuts it down until it is reset. On the WS that reset is the STOP key, after the unit has cooled. ShopTek HIGH DISCH TEMP shows both on one message: a warning above 225°F (107°C), then a STOP fault when the set limit is exceeded. A-O SEPARATOR is neither. It means the fluid separator reached its service interval. High Separator dP on the STS is a differential-pressure fault. The drop across the fluid separator exceeded the set limit, from plugged separator elements or a pressure-sensor failure. It wastes energy and can shut the machine down. Read the separator hours on the Recommended Service screen. Replacing the element is a technician's job, because the separator sits inside the pressurized sump. Main Motor Overload is electrical, not a temperature fault. The main motor overload relay tripped. Common causes are low line voltage, a discharge-pressure setpoint above the compressor's limit, or a misconfigured machine. Wait for the overload to cool, reset per the operator manual, and confirm the load pressure setpoint is not above the machine's rated pressure. A second trip is an electrician or Sullair service. Do not open the electrical enclosure. Drive Fault 14 is not the compressor's discharge temperature. On a Supervisor-era VSD the drive heatsink exceeded 194°F (90°C). A warning is issued at 185°F (85°C). Usual causes are restricted cooling airflow, dust on the heatsink, or high ambient temperature. Do not open the drive cabinet. Capacitors hold charge after power-off.

Every documented Sullair code, by controller

Find the message shown on your display. Each row links to that code's own page.

Sullair ShopTek Controller codes (7)

CodeMeaningPage
HIGH DISCH TEMPHigh discharge temperature warning/tripWhat to do →
PR XDCR FAULTPressure transducer faultWhat to do →
RTD FAULTTemperature sensor (RTD) faultWhat to do →
HIGH PRESSUREOperating pressure above shutdown limitWhat to do →
MOTOR OVERLOADDrive motor overload tripWhat to do →
A-O SEPARATORAir/oil separator service reminderWhat to do →
E-STOPEmergency stop activeWhat to do →

Sullair Supervisor Controller codes (5)

CodeMeaningPage
T1-T5 High (e.g. T2 Discharge High)High temperature fault at a monitored probeWhat to do →
P1 Sump Pressure HighSump pressure high tripWhat to do →
P1-P4 / T1-T5 Sensor FailPressure or temperature sensor failureWhat to do →
dP1 Separator HighSeparator pressure differential highWhat to do →
P3 Oil Pressure LowLow oil pressureWhat to do →

Sullair Supervisor Controller (VSD drive faults) codes (3)

CodeMeaningPage
Drive Fault 14 (Over-temperature)VSD heatsink over-temperatureWhat to do →
Drive Fault 9 (Undervoltage)VSD DC-link undervoltageWhat to do →
VSD Emergency Stop (VSD Code 51)Drive stopped by emergency stop circuitWhat to do →

Sullair Touch Screen (STS) codes (12)

CodeMeaningPage
High Temperature 1 / 2 / 3High compressor temperature tripWhat to do →
High Separator dPHigh pressure drop across air/fluid separatorWhat to do →
High Air Filter dPInlet air filter restrictedWhat to do →
High Oil Filter dPFluid (oil) filter pressure drop highWhat to do →
Main Motor OverloadMain drive motor overload tripWhat to do →
High Sump PressureSump (receiver tank) pressure above limitWhat to do →
Low Sump PressureSump pressure below limitWhat to do →
HIGH AN_ SENSOR / LOW AN_ SENSORAnalog sensor circuit open or shortedWhat to do →
Failed to UnloadCompressor did not unloadWhat to do →
VFD OvertempVariable frequency drive running hotWhat to do →
Replace I/O BatteryController backup battery lowWhat to do →
Sequence Comm ErrorMulti-compressor sequencing communication lostWhat to do →

Sullair WS Controller codes (6)

CodeMeaningPage
High Temperature 1-3 (Air End Discharge Temperature)Air end discharge temperature warning/tripWhat to do →
Separator dP HighSeparator pressure differential tripWhat to do →
E-Stop Push ButtonEmergency stop activatedWhat to do →
Low Line PressurePlant air pressure below setpointWhat to do →
Aux Motor OverloadAuxiliary motor (fan/pump) overload tripWhat to do →
Power InterruptionControl power was interruptedWhat to do →