Start with the symptom
These guides are organized around what the machine is doing, not around
the brand on the nameplate. If the controller is showing a specific code or
message, start with the code lookup instead: each brand page
lists every documented code with its meaning, the likely causes, and the checks
you can safely make yourself. If there is no code, or the display only says
something general like "high temperature" or "shutdown," pick the guide that
matches the symptom:
One rule applies to every guide here: one reset is diagnosis, repeated resets
are damage. If the same fault comes back after a single reset, the condition
behind it is real. Before you reset again, write down the exact code or
message, the pressure and temperature readings on the display, and how long
the machine ran before it tripped. That record is what separates a quick fix
from an expensive service call, and it is the first thing a technician will
ask for.
Anything inside the electrical cabinet, anything still under pressure, and
anything involving the drive or the airend belongs to a qualified technician.
The guides say so wherever it applies.
Frequently asked questions
Which guide do I read for a high-temperature trip, no pressure, or water in the lines?
Start with the symptom, then open the code page if the display already names the fault. A machine tripping on temperature starts with why a rotary screw compressor keeps tripping on high temperature. If Sigma Control 2 shows 0015 A, that is the airend-discharge shutdown: the maximum permissible temperature was exceeded and the controller stopped the machine. On a Sullair touch screen, High Temperature 1 / 2 / 3 means the named probe passed its set high limit. A compressor that runs while plant pressure will not climb starts with running but not building pressure. Kaeser 0044 A means working pressure did not rise above 50 psig within the specified time, or the unit never went into LOAD. Sullair low line pressure means line pressure fell below the set low limit, from demand above capacity, leaks, or open lines. Water at the tools starts with water in compressed air lines. On an Atlas Copco Full-Feature machine with the Elektronikon II, the dryer message is the dewpoint warning: pressure dew point exceeded the programmed warning level, nominal 25 degrees C.
How does the fault-code lookup guide relate to the brand hubs?
The fault-code lookup guide tells you which controller you have and how it writes a fault: Elektronikon Shd and Shdw, AirSmart shutdown numbers versus advisories, Intellisys message numbers and Xe A: versus E:, Sigma Control W versus A, Quincy text or LEDs, and Sullair plain text versus Supervisor channel names. It does not list every code. The list is the brand hub. Open Atlas Copco, Gardner Denver, Ingersoll Rand, Kaeser, Quincy, or Sullair, then the row that matches the display. The five codes at the top of a hub are the ones to know first. On Gardner Denver that high-temperature shutdown is SHUTDOWN #128, airend discharge temperature that exceeded 240°F (116°C).
The compressor keeps shutting down. Do I start with a guide or a code page?
If the display has a specific message, start with that code page, not a general guide. Ingersoll Rand HIGH AIREND TEMPERATURE is the SG-era Intellisys trip when airend discharge temperature reached 228°F (109°C) or higher. Quincy HIGH TEMP means discharge temperature exceeded the programmed shutdown temperature. That QSI page does not give one fixed number. Use why an air compressor keeps shutting down when the trip keeps coming back and you need to sort it into heat, electrical, pressure, a sensor, or controls. Heat still goes to the overheating guide. An overdue filter or separator that is making the machine run hotter is the maintenance guide: the service reminder is there so the item gets changed before the fault. A motor overload is not a temperature problem. One reset after cooldown, then stop.