Atlas Copco Air Compressor Fault Codes: Complete List with Fixes

24 documented codes and fault messages across 11 controller families, each verified against Atlas Copco service documentation, with the meaning, the operator checks, and when it takes a technician.

Home › Atlas Copco

Atlas Copco's GA-series rotary screw compressors are run by the Elektronikon controller family, and the generation on your machine decides what a fault looks like. The Elektronikon II regulator is the button-and-LCD unit on GA machines from the late 1990s and 2000s, including the Full-Feature (FF) packages with a built-in refrigerant dryer and the water-cooled variants. The Elektronikon Mk 5 is the graphic-display generation that followed. Current GA 30+ to GA 90 machines carry the Elektronikon Touch colour touchscreen. Variable-speed machines add a drive layer on top: the GA 37 VSD and GA 45 VSD with the Elektronikon Graphic controller relay converter alarms in hexadecimal (0x1111, 0x2312, 0x2314), GA VSD packages with an integrated drive show F-codes (F020, F023, F006/F011), and the newer GA VSD+ with the Neos inverter uses alphanumeric codes such as A017.

How to read the display. The Elektronikon rarely shows a bare number. It names the sensor, shows the live reading, and adds a tag beside the programmed limit: Shd is a shutdown, Shdw is a shutdown warning that the reading is approaching the trip level, and *Serv Requir* means a service-plan timer or a monitored input has passed its limit. Nominal trip points on GA machines put the element outlet warning around 110 °C and the shutdown around 120 °C. Warnings clear themselves once the condition goes away; shutdowns latch until you fix the cause and press reset. On the Touch controller many faults read as plain conditions with relay designations, so "Motor overload relay (F21) open" is the same kind of message as an older "Overl Fanmotor". Before you reset anything, step through the Status data menu and write down every flagged reading. That snapshot is what a technician will ask for first.

What is safe to do yourself. Most Atlas Copco shutdowns in the field are heat: room ventilation, dirty coolers, low oil. Those checks are operator work and each code page lists them in order. Most of the rest live in the electrical cabinet or the drive, where the instruction book itself says qualified personnel only, and the emergency stop does not make the machine voltage-free. The pages below keep that line.

Five codes to open first. On an Elektronikon II, start with Element Outlet Shd and the shutdown warning that shows before it. *Serv Requir* is the service message. Emergency stop latches the same way on Elektronikon II, Mk 5, and Touch. On a Touch machine, motor overload relay (F21) open is the plain-language overload. Those five are listed again just below, with the controller family beside each one.

Every message in the tables below links to its own page with the documented meaning, the machines that show it, the likely causes, the checks you can make in-house, and the point where it becomes a service call. Each page cites the Atlas Copco instruction book it was verified against.

Five Atlas Copco codes to know first

  1. Element Outlet — Shd (shutdown) (Atlas Copco GA series (Elektronikon II regulator, GA18-GA90 / GA VSD)): Compressor element outlet temperature shutdown.
  2. *Shutd Warn* / Element outlet — Shdw (Atlas Copco GA series (Elektronikon II regulator)): Shutdown warning — element outlet temperature high.
  3. *Serv Requir* (Atlas Copco GA series (Elektronikon II regulator)): Service warning — service plan or input level exceeded.
  4. Emergency Stop (Atlas Copco GA series (Elektronikon II, Mk 5 and Touch controllers)): Emergency stop activated.
  5. Motor overload relay (F21) open (Atlas Copco GA 30+-90 / GA 37+ (Elektronikon Touch)): Main motor overload — compressor does not start or stops.

Frequently asked questions

How do fault codes appear on an Elektronikon II compared with a Mk 5 or Touch?

An Elektronikon II is the button-and-LCD unit. It rarely shows a bare number. The display names the sensor, shows the live reading, and adds a tag beside the programmed limit: Shd for a shutdown, Shdw for a shutdown warning. You clear a latched shutdown with the Rset key after the cause is fixed. A Mk 5 is the graphic-display generation. It shows the shutdown as an on-screen message with the measured value and the programmed level, and you reset it with the confirm button under the reset icon. A Touch controller, on current GA 30+ to GA 90 machines, often spells the condition out in words with a relay designation. Before you reset any of them, step through the Status data and write down every flagged reading. The three styles are on the Element Outlet Shd page, the Mk 5 shutdown page, and the motor overload relay (F21) page.

What does Element Outlet Shd mean?

On the Elektronikon II, Element Outlet Shd means the temperature at the compressor element outlet exceeded the programmed shutdown level, nominally 120 °C, and the controller stopped the machine to protect the airend. The display shows the sensor name, the actual reading, Shd, and the shutdown setting. The earlier message is the shutdown warning, nominally 110 °C, and the compressor keeps running while that warning is up. After a cooldown, the documented checks are room ventilation, oil level, and cooler cleanliness. If it trips again after those, the thermostatic bypass valve, cooler, or sensor needs a technician. Read the Element Outlet Shd page and the shutdown warning page.

What is the difference between a warning and a shutdown on an Elektronikon?

A warning means the reading is approaching a limit and the compressor is still running. On the Elektronikon II that tag is Shdw. A shutdown means the controller has already stopped the machine. That tag is Shd, and it latches until the cause is fixed and you press reset. Warnings clear on their own once the condition goes away. The Mk 5 works the same way: warnings clear by themselves, and a shutdown stays on the display until you press the confirm button under the reset icon. The emergency stop is a separate latch. Pressing it does not make the machine voltage-free. Compare the element-outlet warning with the element-outlet shutdown, and see emergency stop on its own page.

Every documented Atlas Copco code, by controller

Find the message shown on your display. Each row links to that code's own page.

Atlas Copco GA 30+-90 / GA 37+ (Elektronikon Touch) codes (5)

CodeMeaningPage
Motor overload relay (F21) openMain motor overload — compressor does not start or stopsWhat to do →
Circuit breaker (Q15) or fan motor overload (F15) openFan motor circuit trippedWhat to do →
Element outlet / delivery air temperature above normalRunning hot — element outlet or delivery air temperature highWhat to do →
Compressor starts but does not load after delayUnit runs unloaded — will not loadWhat to do →
Safety valve blows after loadingSafety valve venting under loadWhat to do →

Atlas Copco GA 37 VSD / GA 45 VSD (Elektronikon Graphic controller) codes (3)

CodeMeaningPage
Converter alarm 0x1111 — UndervoltageDrive undervoltage faultWhat to do →
Converter alarm 0x2312 — Motor overcurrentDrive detected overcurrent at the motorWhat to do →
Converter alarm 0x2314Drive supply-voltage faultWhat to do →

Atlas Copco GA Full-Feature (Elektronikon II regulator, integrated dryer) codes (1)

CodeMeaningPage
Dewpoint (warning)Dryer dew point temperature too highWhat to do →

Atlas Copco GA Full-Feature (Elektronikon Touch, integrated dryer) codes (1)

CodeMeaningPage
Pressure dew point too high (dryer)Integrated dryer not reaching dew pointWhat to do →

Atlas Copco GA VSD (Elektronikon with integrated drive) codes (3)

CodeMeaningPage
F020Drive overcurrentWhat to do →
F023Drive overvoltageWhat to do →
F006 / F011Inverter or motor overtemperatureWhat to do →

Atlas Copco GA VSD+ (Elektronikon with Neos inverter) codes (1)

CodeMeaningPage
A017Drive not healthy — VSD reports a fault or will not come readyWhat to do →

Atlas Copco GA series (Elektronikon II regulator) codes (4)

CodeMeaningPage
*Shutd Warn* / Element outlet — ShdwShutdown warning — element outlet temperature highWhat to do →
*Serv Requir*Service warning — service plan or input level exceededWhat to do →
Overl Fanmotor (fan motor overload)Fan motor overload shutdownWhat to do →
DP Oil Separ (oil separator pressure difference)Oil separator differential pressure highWhat to do →

Atlas Copco GA series (Elektronikon II regulator, GA18-GA90 / GA VSD) codes (1)

CodeMeaningPage
Element Outlet — Shd (shutdown)Compressor element outlet temperature shutdownWhat to do →

Atlas Copco GA series (Elektronikon II, Mk 5 and Touch controllers) codes (1)

CodeMeaningPage
Emergency StopEmergency stop activatedWhat to do →

Atlas Copco GA series (Elektronikon Mk 5) codes (3)

Atlas Copco GA series, water-cooled (Elektronikon II regulator) codes (1)

CodeMeaningPage
Cool Water Out (warning)Cooling water outlet temperature highWhat to do →