Ingersoll Rand Air Compressor Fault Codes: Complete List with Fixes

33 documented codes and fault messages across 4 controller families, each verified against Ingersoll Rand service documentation, with the meaning, the operator checks, and when it takes a technician.

Home › Ingersoll Rand

Ingersoll Rand has used three fault languages across its rotary screw line, and the first job is working out which one your machine speaks. Older SSR machines in the 10 to 40 HP class carry the original Intellisys controller, which shows numbered messages on a small display: Message -02- through -08-, one number per condition. Larger SG-era SSR packages use a later Intellisys that spells faults out in words: HIGH AIREND TEMPERATURE, HIGH SUMP PRESSURE, CHECK MOTOR ROTATION. Current R-series machines carry the Xe-50M and Xe-70M controllers with structured codes, and the oil-free Sierra machines run the larger Xe-145M, which names sensors by tag (1AVPT, 2ATT, 5OTT) and adds bearing-oil protections that the flooded-screw machines do not have.

How to read the display. On the numbered Intellisys, -02- is motor overload, -03- high discharge air temperature, -04- high discharge pressure, -05- and -06- are sensor failures, and -07- and -08- are the emergency stop pair: -08- simply means someone pressed SET while the button was still pushed in, so twist the button out first. On the Xe controllers the letter is the severity. An A: code is an alarm or warning the machine keeps running through (A:2118 high pressure, A:2128 high temperature, A:4804 service due). An E: code is a trip that shut the machine down (E:0010 emergency stop, E:0020 motor overload, E:0129 excess temperature). Third-party code lists sometimes mislabel these, so the pages here follow the manual's definition. Write down the exact message or code before resetting; on the Xe-145M the sensor tag maps to one specific instrument on the machine.

Two faults that must not be reset and retried. CHECK MOTOR ROTATION on the SG-era controller almost always follows electrical work that swapped two supply phases, and running a screw airend backwards destroys it in minutes. Low Bearing Oil Press on the Sierra machines is the same kind of protection: low oil pressure eats bearings fast. Both stay down until a technician has looked.

The tables below list every documented code by controller. Each links to its own page with the meaning, the machines that show it, the likely causes, what is safe to check in-house, and when the machine needs to stay down until a technician arrives. Each page cites the Ingersoll Rand manual it was verified against.

Five Ingersoll Rand codes to know first

  1. Message -03- (Ingersoll Rand SSR Intellisys (10-40 HP)): High discharge air temperature.
  2. Message -02- (Ingersoll Rand SSR Intellisys (10-40 HP)): Motor overload.
  3. CHECK MOTOR ROTATION (Ingersoll Rand SSR Intellisys (SG-era controller)): No inlet vacuum after start — possible reverse rotation.
  4. E:0129 (Ingersoll Rand Xe-series controller (Xe-50M/Xe-70M, R-series rotary)): Excess temperature shutdown.
  5. E:0010 (Ingersoll Rand Xe-series controller (Xe-50M/Xe-70M, R-series rotary)): Emergency stop trip.

Every documented Ingersoll Rand code, by controller

Find the message shown on your display. Each row links to that code's own page.

Ingersoll Rand SSR Intellisys (10-40 HP) codes (7)

CodeMeaningPage
Message -02-Motor overloadWhat to do →
Message -03-High discharge air temperatureWhat to do →
Message -04-High discharge air pressureWhat to do →
Message -05-Temperature sensor failureWhat to do →
Message -06-Pressure sensor failureWhat to do →
Message -07-Emergency stopWhat to do →
Message -08-Emergency stop button still engagedWhat to do →

Ingersoll Rand SSR Intellisys (SG-era controller) codes (7)

CodeMeaningPage
CHECK INLET CONTROLInlet valve did not confirm movementWhat to do →
LOW UNLOADED SUMPLow sump pressure while unloadedWhat to do →
HIGH SUMP PRESSURESump pressure too highWhat to do →
HIGH AIREND TEMPERATUREAirend discharge over temperature (228°F)What to do →
MOTOR OVERLOAD / FAN MOTOR OVERLOADMain or fan motor overload contact openedWhat to do →
STARTER FAULTStarter fault at startupWhat to do →
CHECK MOTOR ROTATIONNo inlet vacuum after start — possible reverse rotationWhat to do →

Ingersoll Rand Xe-series controller (Xe-145M, Sierra oil-free rotary) codes (5)

CodeMeaningPage
Change Inlet FilterInlet filter restriction warningWhat to do →
Change Oil FilterOil filter pressure drop warningWhat to do →
Low Bearing Oil PressLow bearing oil pressure tripWhat to do →
High Bearing Oil THigh bearing oil temperature tripWhat to do →
1AVPT Failure (Sensor Failure)Sensor failure trip (1AVPT, 2APT, 3APT, 4APT, 2ATT, 3ATT, 5OTT)What to do →

Ingersoll Rand Xe-series controller (Xe-50M/Xe-70M, R-series rotary) codes (14)

CodeMeaningPage
A:0060High separator element differential pressureWhat to do →
A:2118High pressure alarm limit exceededWhat to do →
A:2128High temperature alarm limit exceededWhat to do →
A:3123Run inhibited — temperature below low limitWhat to do →
A:3129Airend discharge temperature above 103°CWhat to do →
A:4804Service dueWhat to do →
E:0010Emergency stop tripWhat to do →
E:0020Main or blower motor overloadWhat to do →
E:0030Remote start failureWhat to do →
E:0040High discharge pressure tripWhat to do →
E:0115Pressure sensor faultWhat to do →
E:0119Excess pressure shutdownWhat to do →
E:0125Temperature sensor faultWhat to do →
E:0129Excess temperature shutdownWhat to do →