❄ Compressor Code Lookup
Home › Ingersoll Rand › 1AVPT Failure (Sensor Failure)
Ingersoll Rand Xe-series controller (Xe-145M, Sierra oil-free rotary) · 1AVPT Failure (Sensor Failure)

What does 1AVPT Failure mean on an Ingersoll Rand compressor?

Short answer: Sensor failure trip (1AVPT, 2APT, 3APT, 4APT, 2ATT, 3ATT, 5OTT). If your Ingersoll Rand Xe-series controller (Xe-145M, Sierra oil-free rotary) is showing 1AVPT Failure (Sensor Failure), the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

Shutdown trip: the controller recognized one of its pressure or temperature sensors as missing or broken, and displays which one in the format '1AVPT Failure'. Warning-level sensor failures (5OPT, 7ATT, 10APT) let the unit keep running.

Which machines show this?

Ingersoll Rand Sierra oil-free rotary screw compressors running the larger Xe-145M controller. Because these are two-stage oil-free machines with a separate bearing lubrication circuit, the fault set looks different from the flooded-screw R-series: plain-text warnings like Change Inlet Filter and Change Oil Filter, hard trips for bearing oil pressure and temperature, and sensor faults reported by tag name — 1AVPT Failure, 2ATT, 5OTT and so on — naming the exact transducer or probe involved. Practical tip: write down the sensor tag exactly as displayed before resetting; that tag maps to one specific instrument on the machine, and it is the difference between a five-minute service call and a guessing game.

What causes it?

  • The named sensor (1AVPT, 2APT, 3APT, 4APT, 2ATT, 3ATT, or 5OTT) reading as missing or broken
  • Loose or damaged connector or cable on that sensor
  • A genuine sensor failure if the same one faults again

Can you fix it yourself?

Sometimes — note exactly which sensor is named, check its connector and cable powered down, and reset once.

Step by step — what to try, in order:

  1. Note exactly which sensor name the display shows before resetting
  2. With the unit powered down, check that sensor's connector and cable for damage or looseness
  3. Reset and see whether the sensor reading returns to a plausible value
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

A repeating sensor fault needs testing and replacement on a pressurized oil-free machine — a service job, because the controller cannot protect what it cannot measure.

When to call: If the same sensor faults again, call a technician to test and replace it — sensor swaps on a pressurized oil-free machine are a service job.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does 1AVPT Failure (Sensor Failure) mean on an Ingersoll Rand Xe-series controller (Xe-145M, Sierra oil-free rotary)?

Sensor failure trip (1AVPT, 2APT, 3APT, 4APT, 2ATT, 3ATT, 5OTT). Shutdown trip: the controller recognized one of its pressure or temperature sensors as missing or broken, and displays which one in the format '1AVPT Failure'. Warning-level sensor failures (5OPT, 7ATT, 10APT) let the unit keep running.

Can I fix 1AVPT Failure (Sensor Failure) on an Ingersoll Rand Xe-series controller (Xe-145M, Sierra oil-free rotary) myself?

Sometimes — note exactly which sensor is named, check its connector and cable powered down, and reset once.

When does 1AVPT Failure (Sensor Failure) on an Ingersoll Rand Xe-series controller (Xe-145M, Sierra oil-free rotary) need a technician?

A repeating sensor fault needs testing and replacement on a pressurized oil-free machine — a service job, because the controller cannot protect what it cannot measure. If the same sensor faults again, call a technician to test and replace it — sensor swaps on a pressurized oil-free machine are a service job.

Verified against service documentation: Ingersoll Rand Xe-series controller (Xe-145M, Sierra oil-free rotary) documentation for 1AVPT Failure (Sensor Failure) (ifixcompressors.com)

Other Ingersoll Rand Xe-series controller (Xe-145M, Sierra oil-free rotary) codes