❄ Compressor Code Lookup
Home › Quincy › Outlet pressure sensor error (PS1)
Quincy QGS 20-30 (INFOLOGIC controller) · Outlet pressure sensor error (PS1)

What does the PS1 outlet pressure sensor error mean on a Quincy QGS?

Short answer: Outlet pressure sensor fault. If your Quincy QGS 20-30 (INFOLOGIC controller) is showing Outlet pressure sensor error (PS1), the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

The controller shuts the compressor down on an error of the outlet pressure sensor; a disconnected pressure transmitter (PS1) is indicated by the flashing general alarm LED with pictograph.

Which machines show this?

Quincy QGS 20-30 hp rotary screw compressors with the compact INFOLOGIC controller, including tank-mounted and integrated-dryer variants. There are no numbered fault codes on this controller: it communicates with LEDs and pictographs — a flashing temperature symbol, a motor symbol, an e-stop symbol, a service wrench — plus small scrollable screens (like d.06 for service-timer hours). Identifying a fault means reading which pictograph is lit or flashing and whether the alarm LED is steady (warning) or flashing (shutdown). Warnings clear themselves when the condition passes; shutdowns need the cause corrected and the unit reset. Larger QGS machines from 40 hp up use the different Airlogic2 controller instead.

What causes it?

  • Pressure transmitter PS1 disconnected from the controller
  • Sensor or wiring fault killing the outlet pressure signal
  • A transient that a single power cycle may clear

Can you fix it yourself?

One power cycle, then stop. The controller shuts down on this error because it has lost its pressure signal — repeated restarts won't bring the sensor back.

Step by step — what to try, in order:

  1. Note the alarm indication shown on the display
  2. Power the unit down and back on once to see if the sensor signal returns
  3. Do not keep restarting if the fault persists
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

The manual restricts sensor and wiring diagnosis to qualified personnel; PS1 sits on the pressurized outlet circuit and connects into the control cabinet, touching both hazard zones.

When to call: Call a technician if the fault does not clear — sensor and wiring diagnosis is restricted to qualified personnel per the manual.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does Outlet pressure sensor error (PS1) mean on a Quincy QGS 20-30 (INFOLOGIC controller)?

Outlet pressure sensor fault. The controller shuts the compressor down on an error of the outlet pressure sensor; a disconnected pressure transmitter (PS1) is indicated by the flashing general alarm LED with pictograph.

Can I fix Outlet pressure sensor error (PS1) on a Quincy QGS 20-30 (INFOLOGIC controller) myself?

One power cycle, then stop. The controller shuts down on this error because it has lost its pressure signal — repeated restarts won't bring the sensor back.

When does Outlet pressure sensor error (PS1) on a Quincy QGS 20-30 (INFOLOGIC controller) need a technician?

The manual restricts sensor and wiring diagnosis to qualified personnel; PS1 sits on the pressurized outlet circuit and connects into the control cabinet, touching both hazard zones. Call a technician if the fault does not clear — sensor and wiring diagnosis is restricted to qualified personnel per the manual.

Verified against service documentation: Quincy QGS 20-30 (INFOLOGIC controller) documentation for Outlet pressure sensor error (PS1) (airenergy.com)

Other Quincy QGS 20-30 (INFOLOGIC controller) codes