Sullair Supervisor Controller · dP1 Separator High

What does dP1 Separator High mean on a Sullair compressor?

Short answer: Separator pressure differential high. If your Sullair Supervisor Controller is showing dP1 Separator High, the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

Pressure drop across the separator is high on a flooded-screw machine, indicating plugged separator elements or a pressure sensor failure.

Which machines show this?

older large-frame Sullair rotary screw compressors — flooded-screw and two-stage industrial packages from the Supervisor era, many still running in plants today. The Supervisor reports by channel: temperatures are T1 through T5, pressures P1 through P4, and differential pressure dP1, so a fault reads like 'T2 Discharge High' or 'P1 Sump Pressure High' rather than a code number. Flooded screws warn at 225 °F on T1 and fault at 235 °F delayed or 255 °F immediate; sensor failures are flagged when a channel reads an impossible value. Practical tip: always record which channel number tripped — T-numbers and P-numbers map to specific probes on the machine, and that number is the first thing a Sullair technician will ask for.

What causes it?

  • Separator elements plugged on the flooded-screw machine
  • Pressure sensor failure mimicking a plugged separator

Can you fix it yourself?

The check is in-house — separator hours in the Maintenance menu and a locked-out look at sensor wiring. The element change is a distributor job.

Step by step — what to try, in order:

  1. Check separator service hours in the Maintenance menu
  2. Schedule separator element replacement
  3. Have sensor wiring visually checked with power locked out
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

The separator element sits inside the pressurized sump, so replacement belongs to your Sullair distributor's technician.

When to call: Call your Sullair distributor to replace the separator element.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does dP1 Separator High mean on a Sullair Supervisor Controller?

Separator pressure differential high. Pressure drop across the separator is high on a flooded-screw machine, indicating plugged separator elements or a pressure sensor failure.

Can I fix dP1 Separator High on a Sullair Supervisor Controller myself?

The check is in-house — separator hours in the Maintenance menu and a locked-out look at sensor wiring. The element change is a distributor job.

When does dP1 Separator High on a Sullair Supervisor Controller need a technician?

The separator element sits inside the pressurized sump, so replacement belongs to your Sullair distributor's technician. Call your Sullair distributor to replace the separator element.

Verified against service documentation: Sullair Supervisor Controller documentation for dP1 Separator High (best-aire.com)