Why does my Atlas Copco Elektronikon Mk 5 keep shutting down?
The Elektronikon Mk 5 has shut the compressor down because element outlet temperature passed the programmed shutdown level, or because the drive motor or the fan motor overloaded. The message stays on the display until the cause is fixed and you press the confirm button under the reset icon.
At a glance
| Severity | Shutdown |
| Can it keep running? | No. The Mk 5 has stopped the unit. The shutdown stays on the display until it is reset. |
| Likely DIY time | The cited Mk 5 steps give no time. Temperature path: cool down, then ventilation, ambient, oil level, and cooler cleanliness. An overload on this same message is not a DIY repair. |
| Typical parts | Cooler and oil level for a temperature trip. No part number in the entry. Motor overload is not a parts swap from this page. |
| Urgency | Stop. Fix the cause before reset. The manual warns that repeated resets without remedying the cause can damage the unit. |
What the controller is measuring
The Elektronikon Mk 5 stops the unit when the element outlet temperature exceeds the programmed shutdown level or when the drive motor or fan motor is overloaded. The shutdown is shown on the display and must be reset after the problem is solved.
The Mk 5 compares element outlet temperature with the shutdown level programmed on that machine. This entry does not give a numeric degree setpoint. The same shutdown also latches when the drive motor or the fan motor overloads, so the value on the screen is what separates a cooling problem from an overload. The Mk 5 shutdown warning and the service-timer warning are different messages. The Elektronikon II element-outlet shutdown is a different controller and a different page.
What causes it?
- Element outlet temperature over the shutdown level — usually ventilation, ambient, oil level, or dirty coolersHow to confirm: After the unit has cooled, check ventilation, ambient temperature, oil level, and whether the cooler is dirty. Read the shutdown message and the value that tripped before you reset.
- Drive motor or fan motor overloadHow to confirm: The shutdown message names the drive motor or the fan motor, not a temperature value. That case is the one the fixability note says is not a DIY fix.
- Repeated resets without fixing the cause, which the manual warns can damage the unitHow to confirm: The same shutdown returns after one reset. The documented steps quote the manual: resetting without remedying the cause can damage the unit.
Step by step
For temperature trips, often yes — cool-down plus ventilation, oil-level, and cooler-cleaning checks resolve most. Motor overload trips are not a DIY fix.
- Read the shutdown message on the display and note the value that tripped
- For temperature trips: check ventilation, ambient temperature, oil level and cooler cleanliness after cool-down
- Solve the problem first — the manual warns that repeatedly resetting without remedying may damage the unit
- Press the confirm button under the reset icon to clear the alarm, then restart
Parts and consumables
What the verified entry already names. OEM catalog numbers are not in that entry, so none are added here.
- Cooler — cleanliness, after cool-down. The entry does not name a replacement cooler or a part number.
- Compressor oil — level check. The entry does not name a grade or a part number.
- Drive motor or fan motor — only when the display says overload. That trip is a technician call, not a listed consumable.
When to call a technician
Any motor overload, or a temperature trip that repeats after basic cooling checks, needs a technician with an ammeter and gauges — resetting blind risks wrecking the airend or motor.
- The display names a drive-motor or fan-motor overload rather than a temperature value.
- A temperature trip returns after ventilation, oil level, and cooler cleanliness have been checked.
- The same shutdown comes back after one reset.
Which controller shows this?
Atlas Copco GA-series rotary screws with the Elektronikon Mk 5 show this as an on-screen shutdown with the measured value and the programmed level. Shutdowns on this controller latch until the problem is fixed and reset. Warnings on the same controller clear on their own once the condition is gone. Atlas Copco GA series (Elektronikon Mk 5) code list.
More questions
Why does a Mk 5 warning clear by itself when this shutdown does not?
On the Elektronikon Mk 5, warnings clear on their own once the condition goes away. A shutdown latches. It stays on the display until the problem is fixed and you press the confirm button under the reset icon. The separate Mk 5 shutdown-warning message and this protective shutdown are not the same event.
Is this the same display text as the Elektronikon II element-outlet shutdown?
No. Element Outlet — Shd is the Elektronikon II regulator message for compressor element outlet temperature, and it has its own page. This Mk 5 message is the protective shutdown that covers element outlet temperature or a drive-motor or fan-motor overload. Read which value the Mk 5 says tripped before you treat it as a cooling problem.
What should I write down before I press reset?
The shutdown message and the value that tripped. That value is what tells a technician whether the stop was temperature or an overload. The cited steps also carry the manual's warning that resetting without remedying the cause can damage the unit.
Verified against service documentation: Atlas Copco GA series (Elektronikon Mk 5) documentation for Shutdown (element outlet temperature / motor overload) (manualslib.com). Last reviewed November 5, 2026.