Gardner Denver AirSmart controller · SHUTDOWN #142 POWER FAILURE

What does Gardner Denver shutdown 142 power failure mean?

Short answer: Loss of power to the package. If your Gardner Denver AirSmart controller is showing SHUTDOWN #142 POWER FAILURE, the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

The controller detected a loss of power to the compressor package. The documented action is to check line voltage.

Which machines show this?

Gardner Denver rotary screw compressors fitted with the first-generation AirSmart microprocessor controller — a wide range of oil-injected packages, including VFD-equipped variable-speed units where the controller supervises the drive. The first-generation AirSmart reports problems as numbered codes: SHUTDOWN #1xx and #2xx faults that stop the machine, and ADVISORY #3xx warnings that let it keep running while flagging maintenance. That numbering matters when you search — the later AirSmart G2 dropped the numbers and displays plain-text fault names instead, so a numbered code on the screen tells you that you are on the earlier controller. Shutdowns clear with Stop/Reset once the machine has stopped; advisories acknowledge with the Enter key.

What causes it?

  • A building power dip or outage cut power to the package
  • A supply problem specific to the compressor's circuit — check whether other equipment on the same feed blinked too
  • Faulty supply wiring or disconnect if failures repeat with no building-wide outage

Can you fix it yourself?

Yes, when it was a genuine outage — wait for stable power, press Stop/Reset, and restart. Repeated power-failure trips with the rest of the building unaffected are an electrical supply fault.

Step by step — what to try, in order:

  1. Check whether the building had a power dip or outage
  2. Verify other equipment on the same supply behaved normally
  3. Press Stop/Reset and restart once power is stable
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

Tracing line-voltage problems in supply wiring and the disconnect is live electrical work that belongs to an electrician, not plant maintenance with a multimeter at a hot panel.

When to call: Call an electrician if power failures repeat with no building-wide outage — supply wiring or the disconnect may be at fault.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does SHUTDOWN #142 POWER FAILURE mean on a Gardner Denver AirSmart controller?

Loss of power to the package. The controller detected a loss of power to the compressor package. The documented action is to check line voltage.

Can I fix SHUTDOWN #142 POWER FAILURE on a Gardner Denver AirSmart controller myself?

Yes, when it was a genuine outage — wait for stable power, press Stop/Reset, and restart. Repeated power-failure trips with the rest of the building unaffected are an electrical supply fault.

When does SHUTDOWN #142 POWER FAILURE on a Gardner Denver AirSmart controller need a technician?

Tracing line-voltage problems in supply wiring and the disconnect is live electrical work that belongs to an electrician, not plant maintenance with a multimeter at a hot panel. Call an electrician if power failures repeat with no building-wide outage — supply wiring or the disconnect may be at fault.

Verified against service documentation: Gardner Denver AirSmart controller documentation for SHUTDOWN #142 POWER FAILURE (best-aire.com)