What does Gardner Denver shutdown 150 motor overtemp mean?

Short answer: Main motor over-temperature. If your Gardner Denver AirSmart controller is showing SHUTDOWN #150 MOTOR OVERTEMP, the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

The digital input programmed for motor over-temperature tripped, meaning the main motor (or its overload relay) got too hot.

Which machines show this?

Gardner Denver rotary screw compressors fitted with the first-generation AirSmart microprocessor controller — a wide range of oil-injected packages, including VFD-equipped variable-speed units where the controller supervises the drive. The first-generation AirSmart reports problems as numbered codes: SHUTDOWN #1xx and #2xx faults that stop the machine, and ADVISORY #3xx warnings that let it keep running while flagging maintenance. That numbering matters when you search — the later AirSmart G2 dropped the numbers and displays plain-text fault names instead, so a numbered code on the screen tells you that you are on the earlier controller. Shutdowns clear with Stop/Reset once the machine has stopped; advisories acknowledge with the Enter key.

What causes it?

  • Main motor overheated after running hard in a hot, poorly ventilated room
  • Motor cooling vents blocked with dust
  • Overload relay tripping — either doing its job or set wrong (the repeat case)

Can you fix it yourself?

Sometimes — let the motor cool fully, clean its vents with power off at the machine controls, improve ventilation, and restart under reduced load. A second trip is not a reset-and-hope situation.

Step by step — what to try, in order:

  1. Let the motor cool completely before any restart attempt
  2. Check for blocked motor cooling vents and clean exterior dust with power off at the machine controls
  3. Improve room ventilation if ambient temperature is high
  4. Press Stop/Reset and restart under reduced load if possible
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

Overload relay settings and motor winding condition are checked with electrical test gear inside the high-voltage cabinet — misjudging either can burn out the most expensive electrical component on the package.

When to call: Call a technician if it trips again — overload relay settings and motor condition require electrical diagnosis.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does SHUTDOWN #150 MOTOR OVERTEMP mean on a Gardner Denver AirSmart controller?

Main motor over-temperature. The digital input programmed for motor over-temperature tripped, meaning the main motor (or its overload relay) got too hot.

Can I fix SHUTDOWN #150 MOTOR OVERTEMP on a Gardner Denver AirSmart controller myself?

Sometimes — let the motor cool fully, clean its vents with power off at the machine controls, improve ventilation, and restart under reduced load. A second trip is not a reset-and-hope situation.

When does SHUTDOWN #150 MOTOR OVERTEMP on a Gardner Denver AirSmart controller need a technician?

Overload relay settings and motor winding condition are checked with electrical test gear inside the high-voltage cabinet — misjudging either can burn out the most expensive electrical component on the package. Call a technician if it trips again — overload relay settings and motor condition require electrical diagnosis.

Verified against service documentation: Gardner Denver AirSmart controller documentation for SHUTDOWN #150 MOTOR OVERTEMP (best-aire.com)