Gardner Denver AirSmart G2 controller · Change Separator

What does Change Separator mean on a Gardner Denver AirSmart G2?

Short answer: Separator element plugged (G2 shutdown). If your Gardner Denver AirSmart G2 controller is showing Change Separator, the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

Differential pressure across the separator element exceeded 15 PSIG (1 bar), forcing a shutdown until the element is changed.

Which machines show this?

Gardner Denver rotary screw compressors with the second-generation AirSmart G2 controller, the color-display successor to the original AirSmart. The key difference for anyone searching a fault: the G2 displays fault names as plain text — "High Discharge Temp", "Drive 1 Fault", "Change Separator" — while the first-generation AirSmart showed numbered codes like SHUTDOWN #128. If your display shows words with no number, you are on a G2. Shutdowns stop the machine and reset with the STOP button once it has come to rest; advisories keep the machine running and clear from the home screen's upper-right (Gardner Denver logo) button. Many G2 packages pair the controller with a variable frequency drive it supervises.

What causes it?

  • Separator element differential pressure exceeded 15 PSIG — the element is plugged
  • Element overdue per the Separator Change Timer advisory history

Can you fix it yourself?

No — resetting only permits short-term operation. Order the correct element and get it changed; a plugged separator costs energy and carries oil downstream until it's replaced.

Step by step — what to try, in order:

  1. Order the correct separator element for your model
  2. Press STOP to reset only for short-term operation until replacement
  3. Check the Separator Change Timer advisory history to confirm the element was overdue
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.
Safety: Pressurized separator tank; element replacement is not a DIY job.

When do you need a technician — and why?

The element sits inside the pressurized air/oil tank, which must be depressurized before opening — the manual explicitly marks this as not a DIY job.

When to call: Call a technician to change the element — the air/oil tank must be depressurized before opening.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does Change Separator mean on a Gardner Denver AirSmart G2 controller?

Separator element plugged (G2 shutdown). Differential pressure across the separator element exceeded 15 PSIG (1 bar), forcing a shutdown until the element is changed.

Can I fix Change Separator on a Gardner Denver AirSmart G2 controller myself?

No — resetting only permits short-term operation. Order the correct element and get it changed; a plugged separator costs energy and carries oil downstream until it's replaced.

When does Change Separator on a Gardner Denver AirSmart G2 controller need a technician?

The element sits inside the pressurized air/oil tank, which must be depressurized before opening — the manual explicitly marks this as not a DIY job. Call a technician to change the element — the air/oil tank must be depressurized before opening.

Verified against service documentation: Gardner Denver AirSmart G2 controller documentation for Change Separator (best-aire.com)