Gardner Denver AirSmart G2 controller · High Inlet Temp

What does High Inlet Temp mean on a Gardner Denver AirSmart G2?

Short answer: High package inlet temperature (G2 advisory). If your Gardner Denver AirSmart G2 controller is showing High Inlet Temp, the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

Air entering the package exceeded 113°F (45°C) (104°F/40°C on some models). The documented action is to wait for the ambient temperature to cool.

Which machines show this?

Gardner Denver rotary screw compressors with the second-generation AirSmart G2 controller, the color-display successor to the original AirSmart. The key difference for anyone searching a fault: the G2 displays fault names as plain text — "High Discharge Temp", "Drive 1 Fault", "Change Separator" — while the first-generation AirSmart showed numbered codes like SHUTDOWN #128. If your display shows words with no number, you are on a G2. Shutdowns stop the machine and reset with the STOP button once it has come to rest; advisories keep the machine running and clear from the home screen's upper-right (Gardner Denver logo) button. Many G2 packages pair the controller with a variable frequency drive it supervises.

What causes it?

  • Compressor room air above 113°F (104°F on some models)
  • Hot compressor exhaust recirculating to the package inlet
  • Not enough louver or ventilation capacity for the room

Can you fix it yourself?

Yes — this is a ventilation problem: cool the room, stop the recirculation, and reset the advisory with the logo button once the temperature drops.

Step by step — what to try, in order:

  1. Add ventilation or open louvers to cool the compressor room
  2. Prevent hot compressor exhaust from recirculating to the inlet
  3. Reset the advisory with the logo button once the room cools
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

A room that runs this hot every day needs ducting changes sized by an installer — undersized intake or exhaust ducting will keep the machine flirting with temperature faults all summer.

When to call: Call an installer if the room regularly runs this hot — ducting changes may be needed.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does High Inlet Temp mean on a Gardner Denver AirSmart G2 controller?

High package inlet temperature (G2 advisory). Air entering the package exceeded 113°F (45°C) (104°F/40°C on some models). The documented action is to wait for the ambient temperature to cool.

Can I fix High Inlet Temp on a Gardner Denver AirSmart G2 controller myself?

Yes — this is a ventilation problem: cool the room, stop the recirculation, and reset the advisory with the logo button once the temperature drops.

When does High Inlet Temp on a Gardner Denver AirSmart G2 controller need a technician?

A room that runs this hot every day needs ducting changes sized by an installer — undersized intake or exhaust ducting will keep the machine flirting with temperature faults all summer. Call an installer if the room regularly runs this hot — ducting changes may be needed.

Verified against service documentation: Gardner Denver AirSmart G2 controller documentation for High Inlet Temp (best-aire.com)