Sullair Touch Screen (STS) · High Separator dP

What does High Separator dP mean on a Sullair compressor?

Short answer: High pressure drop across air/fluid separator. If your Sullair Touch Screen (STS) is showing High Separator dP, the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

The pressure differential across the fluid separator has exceeded the set limit, indicating plugged separator elements or a pressure sensor failure. This wastes energy and can shut the machine down.

Which machines show this?

current-generation Sullair stationary rotary screw compressors — the LS-series and related packages built from the late 2010s onward — fitted with the 10-inch Sullair Touch Screen (STS) controller. The STS spells out problems as plain-English named faults and warnings ('High Temperature 1', 'Failed to Unload', 'Replace I/O Battery') rather than bare code numbers, and pairs them with live readings and a Recommended Service screen that tracks filter and separator hours. Warnings keep the machine running; faults shut it down until reset. Practical tip: before clearing anything, photograph the fault screen and the Recommended Service page — the service-hour counters usually point straight at the consumable that caused the trip.

What causes it?

  • Separator elements plugged — usually simply at the end of their service life
  • Pressure sensor failure giving a false differential reading

Can you fix it yourself?

The check is in-house — read the separator hours on the Recommended Service screen and confirm connectors are seated. The element change is not.

Step by step — what to try, in order:

  1. Note the separator service hours on the Recommended Service screen — a separator at end of life is the most common cause
  2. Have the separator element replaced at the next service window
  3. Check that sensor wiring connectors are seated (visual check only, power off)
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

The separator sits inside the pressurized sump, so replacement goes to a qualified technician from your Sullair distributor.

When to call: Call your Sullair distributor to replace the separator element — it sits inside the pressurized sump and must be changed by a qualified technician.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does High Separator dP mean on a Sullair Touch Screen (STS)?

High pressure drop across air/fluid separator. The pressure differential across the fluid separator has exceeded the set limit, indicating plugged separator elements or a pressure sensor failure. This wastes energy and can shut the machine down.

Can I fix High Separator dP on a Sullair Touch Screen (STS) myself?

The check is in-house — read the separator hours on the Recommended Service screen and confirm connectors are seated. The element change is not.

When does High Separator dP on a Sullair Touch Screen (STS) need a technician?

The separator sits inside the pressurized sump, so replacement goes to a qualified technician from your Sullair distributor. Call your Sullair distributor to replace the separator element — it sits inside the pressurized sump and must be changed by a qualified technician.

Verified against service documentation: Sullair Touch Screen (STS) documentation for High Separator dP (sullair.com)