Sullair Touch Screen (STS) · Low Sump Pressure

Why is sump pressure low on my Sullair compressor?

Short answer: Sump pressure below limit. If your Sullair Touch Screen (STS) is showing Low Sump Pressure, the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

Compressor sump pressure has fallen below the set limit. The manual attributes this to a bad pressure sensor or connections, or the machine failing to start properly.

Which machines show this?

current-generation Sullair stationary rotary screw compressors — the LS-series and related packages built from the late 2010s onward — fitted with the 10-inch Sullair Touch Screen (STS) controller. The STS spells out problems as plain-English named faults and warnings ('High Temperature 1', 'Failed to Unload', 'Replace I/O Battery') rather than bare code numbers, and pairs them with live readings and a Recommended Service screen that tracks filter and separator hours. Warnings keep the machine running; faults shut it down until reset. Practical tip: before clearing anything, photograph the fault screen and the Recommended Service page — the service-hour counters usually point straight at the consumable that caused the trip.

What causes it?

  • Bad pressure sensor or its connections
  • The machine failing to start and build pressure properly

Can you fix it yourself?

Partly — confirm the machine actually started, restart once after a full blowdown, and sanity-check the displayed pressure against line gauges.

Step by step — what to try, in order:

  1. Verify the compressor actually started and built pressure
  2. Restart once after a full stop and blowdown
  3. Note whether the displayed pressure reading looks plausible compared to line gauges
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

A repeating fault needs the sensor, wiring, and tubing tested by service — the controller can't run a compressor on a pressure reading it can't trust.

When to call: Call service to check the pressure sensor, wiring, and tubing if the fault repeats.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does Low Sump Pressure mean on a Sullair Touch Screen (STS)?

Sump pressure below limit. Compressor sump pressure has fallen below the set limit. The manual attributes this to a bad pressure sensor or connections, or the machine failing to start properly.

Can I fix Low Sump Pressure on a Sullair Touch Screen (STS) myself?

Partly — confirm the machine actually started, restart once after a full blowdown, and sanity-check the displayed pressure against line gauges.

When does Low Sump Pressure on a Sullair Touch Screen (STS) need a technician?

A repeating fault needs the sensor, wiring, and tubing tested by service — the controller can't run a compressor on a pressure reading it can't trust. Call service to check the pressure sensor, wiring, and tubing if the fault repeats.

Verified against service documentation: Sullair Touch Screen (STS) documentation for Low Sump Pressure (sullair.com)

Other Sullair Touch Screen (STS) codes