Gardner Denver AirSmart controller · SHUTDOWN #128 HIGH DISCH TEMP

What does Gardner Denver shutdown 128 high discharge temp mean?

Shutdown

Shutdown #128 means airend discharge temperature exceeded 240°F (116°C) and the AirSmart controller stopped the compressor. After it cools, the documented checks are the oil sight glass, the oil-cooler faces, and room ventilation.

At a glance

SeverityShutdown
Can it keep running?No. The AirSmart stopped the compressor at 240°F (116°C).
Likely DIY timeThe cited AirSmart steps give no time. Cool fully, read the oil sight glass, clean the oil-cooler faces with the machine off, and correct room ventilation.
Typical partsOil level and the oil-cooler faces. A repeat points at the thermal valve or the oil system. No part number in the entry.
UrgencyStop and let it cool. Clear it with Stop/Reset only after the checks.

What the controller is measuring

Temperature at the airend discharge exceeded 240°F (116°C) and the controller stopped the compressor to prevent damage. This is one of the most common shutdowns on rotary screw machines.

Shutdown #128 is airend discharge temperature above 240°F (116°C). Advisory #316 is the high-airend-discharge-temperature warning, and the compressor keeps running on an advisory. Shutdown #137 is a rapid rise in airend discharge temperature, which is a rate trip rather than the 240°F limit. Shutdown #122 is package (plant-air) discharge temperature, and #125 is separator temperature. Those are other sensors. Shutdowns clear with Stop/Reset once the machine has stopped. Advisories acknowledge with the Enter key.

What causes it?

  1. Oil level low at the sight glass — less oil means less heat carried away from the airendHow to confirm: After a full cool-down, read the oil level at the sight glass. Low oil is the first documented cause.
  2. Oil cooler faces packed with dust and lintHow to confirm: With the machine off, look at the oil-cooler faces for dust, lint, and debris, and clean them.
  3. Hot intake air from a badly ventilated room driving discharge temperature past 240°FHow to confirm: Check whether the room is feeding hot air to the intake. The documented step is to improve ventilation.
  4. Thermal valve or oil system fault that keeps cooling oil from circulating properly (the repeat case)How to confirm: The shutdown returns after cooling, cleaning, and a correct oil level. The cited remaining cause is a thermal valve or oil-system fault, which is technician work.

Step by step

Usually, yes — this is the most common rotary-screw shutdown, and cooling, cleaning, and topping up oil clears most of them. If it trips again after that, stop restarting it.

  1. Let the machine cool fully, then check the oil level at the sight glass
  2. Clean the oil cooler faces of dust, lint, and debris with the machine off
  3. Improve room ventilation — hot intake air drives discharge temperature up
  4. Press Stop/Reset to clear the fault and restart while watching the temperature

Parts and consumables

What the verified entry already names. OEM catalog numbers are not in that entry, so none are added here.

  • Compressor oil — sight-glass level after a full cool-down. The entry does not name a grade or a part number.
  • Oil cooler — clean the faces. No cooler part number is in the entry.
  • Thermal valve or the oil system — the repeat-shutdown inspection. No part number is in the entry.

When to call a technician

A machine that keeps hitting 240°F despite good oil and clean coolers has a thermal valve or oil-circuit fault, and diagnosing that means opening the pressurized oil system with the right instruments.

  • Shutdown #128 returns after the machine has cooled, the cooler faces are clean, and the oil level is correct.
  • The remaining suspect is the thermal valve or the oil circuit. The guidance says that means opening the pressurized oil system with the right instruments.
  • The fault on the screen is #122 or #125 instead. Those are different temperature sensors.
When to call: Call a technician if the shutdown repeats after cooling, cleaning, and oil-level checks — thermal valve or oil system faults need professional service.
Need a compressor tech? If this Gardner Denver fault still needs a technician after the checks above, see who services industrial air compressors in Nashville, TN or Birmingham, AL. Those lists are independently compiled from each company's own published information.

Which controller shows this?

First-generation Gardner Denver AirSmart controller, the one that uses numbered shutdowns and advisories. A numbered code on the screen is this controller. The later AirSmart G2 uses plain-text fault names and does not use #128. Shutdowns clear with Stop/Reset once the machine has stopped. Gardner Denver AirSmart controller code list.

More questions

What is the difference between shutdown 128 and advisory 316?

Both are high airend discharge temperature on the first-generation AirSmart. Advisory #316 leaves the compressor running. Shutdown #128 means discharge temperature exceeded 240°F (116°C) and the controller stopped it. Shutdown #137 is the rapid-rise trip on airend discharge temperature, which is a different test than the 240°F limit.

Is shutdown 122 the same sensor as 128?

No. Shutdown #122 is high package discharge temperature, the plant-air temperature. Shutdown #125 is high separator temperature. Shutdown #128 is the airend discharge. The number on the screen is which sensor tripped.

How is a shutdown cleared on this AirSmart, once the cause is fixed?

Shutdowns clear with Stop/Reset once the machine has stopped. The steps for #128 say to do that while watching the temperature, after it has cooled and the oil level and cooler faces have been checked. An advisory acknowledges with the Enter key. #128 is a shutdown, so the key is Stop/Reset.

Verified against service documentation: Gardner Denver AirSmart controller documentation for SHUTDOWN #128 HIGH DISCH TEMP (best-aire.com). Last reviewed November 5, 2026.