Sullair Touch Screen (STS) · High Temperature 1 / 2 / 3

Why does my Sullair compressor keep shutting down on high temperature?

Shutdown

High Temperature 1, 2, or 3 means the named probe exceeded its set high limit and the STS shut the compressor down. Sullair's cause list for this fault starts with ambient above 105°F (41°C), low fluid, a stuck thermal valve, dirty cooler fins, or a failed temperature probe.

At a glance

SeverityShutdown
Can it keep running?No. High Temperature 1, 2, or 3 is a High Temp Fault. The STS shuts the compressor down.
Likely DIY timeThe cited STS steps give no time. Check ambient and ventilation, the fluid level once the unit is stopped and cool, the cooler fins, and on a water-cooled unit the cooling-water valves and pump.
Typical partsCompressor fluid (level only), cooler fins, and on a water-cooled unit the water valves and pump. A repeat points at the thermal valve or the temperature probe. No part number in the entry.
UrgencyStop and let it cool. Hot surfaces. Check the fluid level only after cooldown.

What the controller is measuring

The temperature at the indicated probe has exceeded the set high limit and the controller shuts the compressor down (High Temp Fault). Sullair lists high ambient above 105°F (41°C), low fluid level, a stuck thermal valve, dirty cooler fins, or a failed temperature probe as the usual causes.

The STS watches the probe named on the screen, High Temperature 1, 2, or 3, against that probe's set high limit. This entry does not give the limit as a number, and it does not say which physical point each probe number is. 105°F (41°C) in the cause list is ambient temperature, not the trip setpoint. A failed probe is a separate fault, HIGH AN_ SENSOR or LOW AN_ SENSOR. The water-valve step applies to water-cooled units. An air-cooled package uses the cooler-fin and ventilation checks.

What causes it?

  1. Ambient above 105°F (41°C) or poor ventilation around the packageHow to confirm: Read the room temperature. Sullair lists high ambient above 105°F (41°C), or poor ventilation around the package, as a cause. Improve ventilation if that is the case.
  2. Compressor fluid level lowHow to confirm: With the unit stopped and cooled, check the compressor fluid level and top up to the proper level if it is low. The entry does not name the fluid grade.
  3. Thermal valve stuck, or cooler fins matted with dustHow to confirm: Look at the cooler fins and fan blades for dust and debris. A stuck thermal valve is the repeat case, not this visual check.
  4. On water-cooled units, water valves closed or the pump offHow to confirm: On a water-cooled unit, confirm the cooling-water valves are open and the pump is running. Skip this step on an air-cooled package.
  5. Failed temperature probe (the case that persists after everything else checks out)How to confirm: The trip remains after ambient, fluid level, and the cooler check out. The cited remaining causes are a stuck thermal valve or a failed temperature probe.

Step by step

Often, yes — Sullair's own cause list starts with ambient, fluid level, and dirty coolers, all of which plant staff can correct before resetting with Stop.

  1. Check ambient temperature and improve ventilation around the package if the room is above 105°F (41°C)
  2. With the unit stopped and cooled, check the compressor fluid level and top up to the proper level
  3. Clean the cooler fins and fan blades of dust and debris
  4. On water-cooled units, confirm cooling water valves are open and the pump is running
  5. After cooldown, press Stop to reset and restart while watching the temperature
Safety: Hot surfaces — allow the compressor to cool before checking fluid level.

Parts and consumables

What the verified entry already names. OEM catalog numbers are not in that entry, so none are added here.

  • Compressor fluid — level check once stopped and cool, then top up to the proper level. The entry does not name a grade or a part number.
  • Cooler fins and fan blades — clean dust and debris. No part number is in the entry.
  • Thermal valve or temperature probe — the repeat-trip items. A failed probe is also the separate HIGH AN_ SENSOR / LOW AN_ SENSOR fault. No part number is in the entry.
  • Cooling-water valves and pump — water-cooled units only, a check that they are open and running, not a part number.

When to call a technician

Repeat trips after cleaning and top-up point at the thermal valve or temperature probe, which need gauge-and-meter diagnosis to replace correctly.

  • The trip returns after the cooler is clean and the fluid level is corrected.
  • The remaining suspect is the thermal valve or the temperature probe.
  • The package is still hot. The safety line says to let it cool before the fluid-level check.
When to call: Call a service technician if the trip repeats after cleaning the cooler and correcting fluid level — the thermal valve or temperature sensor may need replacement.
Need a compressor tech? If this Sullair fault still needs a technician after the checks above, see who services industrial air compressors in Nashville, TN or Birmingham, AL. Those lists are independently compiled from each company's own published information.

Which controller shows this?

Current Sullair stationary rotary screws, LS-series and related packages from the late 2010s onward, with the 10-inch Sullair Touch Screen. The STS spells faults out by name. Warnings keep the machine running. A fault such as High Temperature shuts it down until reset. Photograph the fault screen before you clear it. Sullair Touch Screen (STS) code list.

More questions

Which point in the package is probe 1, probe 2, and probe 3?

This entry does not say. The STS message is that the temperature at the indicated probe exceeded the set high limit. It does not publish a map of which probe is the airend, the separator, or another point, and it does not publish the numeric high limit. Use the probe name on the screen. A failed probe, when the other checks are good, is the separate HIGH AN_ SENSOR or LOW AN_ SENSOR fault.

Is 105°F the temperature that trips the compressor?

No. 105°F (41°C) is the ambient figure in Sullair's cause list: high ambient above that, or poor ventilation around the package. The trip itself is the named probe's set high limit. This entry does not give that limit as a number.

The package is air-cooled. Do the water valves still get checked?

No. The water-valve step is written for water-cooled units: confirm the cooling-water valves are open and the pump is running. An air-cooled package uses the ambient, ventilation, fluid-level, and cooler-fin checks.

Verified against service documentation: Sullair Touch Screen (STS) documentation for High Temperature 1 / 2 / 3 (sullair.com). Last reviewed November 5, 2026.