Gardner Denver AirSmart controller · SHUTDOWN #134 HIGH INLET TEMP

What does Gardner Denver shutdown 134 high inlet temp mean?

Short answer: High package inlet temperature. If your Gardner Denver AirSmart controller is showing SHUTDOWN #134 HIGH INLET TEMP, the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

Air entering the package exceeded 113°F (45°C) — the ambient temperature is too high for safe compressor operation.

Which machines show this?

Gardner Denver rotary screw compressors fitted with the first-generation AirSmart microprocessor controller — a wide range of oil-injected packages, including VFD-equipped variable-speed units where the controller supervises the drive. The first-generation AirSmart reports problems as numbered codes: SHUTDOWN #1xx and #2xx faults that stop the machine, and ADVISORY #3xx warnings that let it keep running while flagging maintenance. That numbering matters when you search — the later AirSmart G2 dropped the numbers and displays plain-text fault names instead, so a numbered code on the screen tells you that you are on the earlier controller. Shutdowns clear with Stop/Reset once the machine has stopped; advisories acknowledge with the Enter key.

What causes it?

  • Compressor room ambient temperature above 113°F
  • Hot exhaust air from the compressor recirculating back to its own inlet
  • Inadequate louvers, doors, or ventilation for the heat the package puts out

Can you fix it yourself?

Yes — this is a room problem, not a machine problem. Open louvers, add ventilation, stop exhaust recirculation, let the room cool, and restart.

Step by step — what to try, in order:

  1. Open doors/louvers or add ventilation to lower room temperature
  2. Make sure hot exhaust air from the compressor is not recirculating to its inlet
  3. Wait for the room to cool, then press Stop/Reset and restart
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

A room that routinely exceeds 113°F needs ducting or machine relocation designed by an installer — sizing intake and exhaust ducting wrong just moves the overheating problem around.

When to call: Call an installer or technician if the compressor room routinely exceeds 113°F — ducting or relocation may be required.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does SHUTDOWN #134 HIGH INLET TEMP mean on a Gardner Denver AirSmart controller?

High package inlet temperature. Air entering the package exceeded 113°F (45°C) — the ambient temperature is too high for safe compressor operation.

Can I fix SHUTDOWN #134 HIGH INLET TEMP on a Gardner Denver AirSmart controller myself?

Yes — this is a room problem, not a machine problem. Open louvers, add ventilation, stop exhaust recirculation, let the room cool, and restart.

When does SHUTDOWN #134 HIGH INLET TEMP on a Gardner Denver AirSmart controller need a technician?

A room that routinely exceeds 113°F needs ducting or machine relocation designed by an installer — sizing intake and exhaust ducting wrong just moves the overheating problem around. Call an installer or technician if the compressor room routinely exceeds 113°F — ducting or relocation may be required.

Verified against service documentation: Gardner Denver AirSmart controller documentation for SHUTDOWN #134 HIGH INLET TEMP (best-aire.com)