Kaeser Sigma Control 2 · 0015 A — Airend discharge temperature ADT ⇞

What does Kaeser alarm 0015 A (airend temperature too high) mean?

Shutdown

0015 A means the airend discharge temperature exceeded the maximum Sigma Control 2 allows, and the controller shut the machine down. Dirty cooler surfaces, ventilation outside the machine's limits, and low cooling oil are the documented causes to check after it cools.

At a glance

SeverityShutdown
Can it keep running?No. 0015 A is an alarm. Sigma Control 2 has shut the machine down.
Likely DIY timeThe cited Sigma Control 2 steps give no time. The documented work is cooldown, then ventilation, cooler cleaning, and the oil-level sight glass with the machine off and depressurized.
Typical partsCooler surfaces and cooling oil (level only). No oil grade and no part number in the entry. A repeat points at thermostatic control, which is a technician check.
UrgencyStop and let it cool before you touch panels.

What the controller is measuring

The maximum permissible airend discharge temperature (ADT) was exceeded and the controller shut the machine down. This is the classic overheat trip on Kaeser rotary screw compressors, typically caused by poor cooling or low oil.

0015 A is airend discharge temperature (ADT) above the maximum the controller allows. This entry does not give that maximum as a number. The warning ahead of it is 0008 W, which leaves the machine running. 0017 A is the ADT safety shutdown, and 0043 A is ADT rising too fast (dT/dt). On Sigma Control 2 a W message keeps the machine running and an A message shuts it down.

What causes it?

  1. Cooler surfaces blocked with dust — a dirty cooler cannot shed heatHow to confirm: Look at the cooler surfaces for dust and debris. The documented step is to clean them after the machine has cooled.
  2. Ambient temperature or ventilation outside the machine's limits, or cooling air openings blockedHow to confirm: Check that ambient temperature and ventilation are within the machine's specified limits, and that the cooling-air inlet and outlet are not blocked or too close to a wall.
  3. Cooling oil level lowHow to confirm: With the machine off and depressurized, check the cooling-oil level by the sight-glass procedure in the operator manual.
  4. Temperature monitoring or cooling-system fault if the trip repeats after cleanupHow to confirm: The trip returns after cooler cleaning, oil level, and ventilation are corrected. That is the case the guidance sends to Kaeser service for the thermostatic control and cooling system.

Step by step

Often, yes — cooldown, cooler cleaning, oil top-up (machine off and depressurized), and ventilation fixes clear most ADT shutdowns.

  1. Let the machine cool down before doing anything else.
  2. Check that ambient temperature and ventilation are within the machine's specified limits (cooling air inlet and outlet not blocked or too close to a wall).
  3. Clean the cooler surfaces of dust and debris.Safety: the machine shut down hot. Let it cool before you touch the panels.
  4. Check the cooling oil level with the machine off and depressurized per the operator manual sight glass procedure.
  5. Acknowledge the alarm with the reset key after cooldown and monitor the next run.
Safety: Machine shuts down hot — allow cooldown before touching panels.

Parts and consumables

What the verified entry already names. OEM catalog numbers are not in that entry, so none are added here.

  • Cooler surfaces — clean dust and debris. No cooler part number is in the entry.
  • Cooling oil — level check on the sight glass with the machine off and depressurized. The entry does not name a grade or a part number.
  • Thermostatic control and the cooling system — the repeat-trip check for a Kaeser technician. The entry does not name a valve kit or a sensor part number.

When to call a technician

A repeat trip after those basics needs Kaeser service to check the thermostatic control and cooling system with instruments rather than another reset.

  • 0015 A returns after the cooler is clean, the oil level is corrected, and ventilation is within limits.
  • The remaining suspect is thermostatic control or the cooling system, which the guidance assigns to Kaeser service.
  • The machine is still hot. Let it cool before any panel or oil-level check.
When to call: Call a Kaeser service technician if the trip repeats after cleaning the cooler and correcting oil level and ventilation.
Need a compressor tech? If this Kaeser fault still needs a technician after the checks above, see who services industrial air compressors in Nashville, TN or Birmingham, AL. Those lists are independently compiled from each company's own published information.

Which controller shows this?

Sigma Control 2 is the controller on current Kaeser ASD, BSD, CSD, DSD, ESD and related rotary screws, built since roughly 2011. It reports faults as a four-digit number plus a letter. The A on 0015 means the machine has shut down. The matching warning is 0008 W, which leaves it running. Kaeser Sigma Control 2 code list.

More questions

What is the difference between 0008 W and 0015 A?

0008 W is the airend-discharge-temperature warning: the value is approaching the shutdown limit and the machine keeps running. 0015 A is the alarm: maximum permissible ADT was exceeded and Sigma Control 2 has shut the machine down. The same controller also has 0017 A, the ADT safety shutdown, and 0043 A, ADT rising too fast. Acting on the W message is how you avoid the A shutdown.

Does 0015 A mean the oil-change hour counter has expired?

Not by itself. 0026 W is the cooling-oil maintenance interval. 0071 W is the low oil-level warning. 0015 A is the temperature shutdown. Low cooling oil is one documented cause of 0015 A, checked on the sight glass with the machine off and depressurized. The hour counter is a different message.

Do the cited steps say to raise the ADT limit?

They do not. The documented response is cooldown, ventilation, cooler cleaning, and the oil-level check. If the trip returns after those checks, the cited guidance sends the machine to a Kaeser technician for the thermostatic control and the cooling system.

Verified against service documentation: Kaeser Sigma Control 2 documentation for 0015 A — Airend discharge temperature ADT ⇞ (airsolcan.com). Last reviewed November 5, 2026.