What does ADT (A) mean on a Kaeser Sigma Control?

Short answer: Airend discharge temperature exceeded (original Sigma Control). If your Kaeser Sigma Control (original) is showing ADT (A), the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

On first-generation Sigma Control units, the alarm message "ADT" means the maximum airend discharge temperature was exceeded and the package shut down. A "ADT dT/dt" alarm exists for excessive rate of temperature rise.

Which machines show this?

first-generation Kaeser rotary screw compressors fitted with the original Sigma Control — the green-keypad, text-display controller Kaeser introduced around the turn of the 2000s on its direct-drive screw packages. This controller shows faults as short lower-case text messages with a severity letter: (A) for an alarm that shuts the machine down, (W) for a warning it keeps running through — so 'ADT (A)' is an airend-temperature shutdown while 'separator dp (W)' is a clogging separator flagged early. Alarms are acknowledged with the reset key after the cause is fixed. Practical tip: these machines also enforce a minimum start temperature of +3 °C, so a winter no-start in an unheated room is often the controller doing its job, not a fault.

What causes it?

  • Insufficient ventilation or ambient above 40°C
  • Cooler dirty, or the cooling air outlet too close to a wall
  • Oil level low
  • Oil filter overdue

Can you fix it yourself?

Often, yes — the manual's own remedy list is ventilation, cooler cleaning, oil level, and an oil filter renewal, all operator-level, then reset after cooldown.

Step by step — what to try, in order:

  1. Ensure sufficient ventilation and keep ambient temperature below 40°C.
  2. Clean the cooler; make sure the cooling air outlet is not too near a wall.
  3. Check the oil level.
  4. Renew the oil filter if due, then reset the alarm with the reset key after cooldown.
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

A repeating overheat trip after that cleanup needs a Kaeser service agent to check the thermostatic control and oil circulation with instruments.

When to call: Call a Kaeser service agent if the overheat trip repeats after cooling-system cleanup.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does ADT (A) mean on a Kaeser Sigma Control (original)?

Airend discharge temperature exceeded (original Sigma Control). On first-generation Sigma Control units, the alarm message "ADT" means the maximum airend discharge temperature was exceeded and the package shut down. A "ADT dT/dt" alarm exists for excessive rate of temperature rise.

Can I fix ADT (A) on a Kaeser Sigma Control (original) myself?

Often, yes — the manual's own remedy list is ventilation, cooler cleaning, oil level, and an oil filter renewal, all operator-level, then reset after cooldown.

When does ADT (A) on a Kaeser Sigma Control (original) need a technician?

A repeating overheat trip after that cleanup needs a Kaeser service agent to check the thermostatic control and oil circulation with instruments. Call a Kaeser service agent if the overheat trip repeats after cooling-system cleanup.

Verified against service documentation: Kaeser Sigma Control (original) documentation for ADT (A) (airsolcan.com)