❄ Compressor Code Lookup
Home › Kaeser › no press. buildup (A)
Kaeser Sigma Control (original) · no press. buildup (A)

Why won't my Kaeser compressor build pressure?

Short answer: No pressure buildup. If your Kaeser Sigma Control (original) is showing no press. buildup (A), the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

The package cannot build pressure — package pressure does not rise above 3.5 bar within the preset period. Documented checks include leaks, the inlet valve, and the minimum pressure/check valve (MPCV).

Which machines show this?

first-generation Kaeser rotary screw compressors fitted with the original Sigma Control — the green-keypad, text-display controller Kaeser introduced around the turn of the 2000s on its direct-drive screw packages. This controller shows faults as short lower-case text messages with a severity letter: (A) for an alarm that shuts the machine down, (W) for a warning it keeps running through — so 'ADT (A)' is an airend-temperature shutdown while 'separator dp (W)' is a clogging separator flagged early. Alarms are acknowledged with the reset key after the cause is fixed. Practical tip: these machines also enforce a minimum start temperature of +3 °C, so a winter no-start in an unheated room is often the controller doing its job, not a fault.

What causes it?

  • Leak in the package or nearby piping
  • Inlet valve not opening (documented check)
  • Minimum pressure/check valve (MPCV) defective

Can you fix it yourself?

Partly — check the package and piping for leaks, and compare the controller's pressure reading against the tank gauge; note any mismatch for the technician.

Step by step — what to try, in order:

  1. Check the complete package and nearby piping for leaks.
  2. Compare the controller's internal pressure reading with the gauge on the oil separator tank and note any mismatch for the technician.
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

If no leak shows, the inlet valve and MPCV need technician diagnosis on the pressurized circuit — the two readings disagreeing also points at a sensor.

When to call: Call Kaeser service if no leak is found — inlet valve and MPCV diagnosis is technician work.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does no press. buildup (A) mean on a Kaeser Sigma Control (original)?

No pressure buildup. The package cannot build pressure — package pressure does not rise above 3.5 bar within the preset period. Documented checks include leaks, the inlet valve, and the minimum pressure/check valve (MPCV).

Can I fix no press. buildup (A) on a Kaeser Sigma Control (original) myself?

Partly — check the package and piping for leaks, and compare the controller's pressure reading against the tank gauge; note any mismatch for the technician.

When does no press. buildup (A) on a Kaeser Sigma Control (original) need a technician?

If no leak shows, the inlet valve and MPCV need technician diagnosis on the pressurized circuit — the two readings disagreeing also points at a sensor. Call Kaeser service if no leak is found — inlet valve and MPCV diagnosis is technician work.

Verified against service documentation: Kaeser Sigma Control (original) documentation for no press. buildup (A) (airsolcan.com)

Other Kaeser Sigma Control (original) codes