What does HIGH AN SENSOR or LOW AN SENSOR mean on a Sullair STS?
HIGH AN_ SENSOR means an open circuit on the named analog input, and LOW AN_ SENSOR means a short. The STS shuts the compressor down because it can no longer trust that pressure or temperature reading.
At a glance
| Severity | Shutdown |
| Can it keep running? | No. The STS shuts the compressor down because it can no longer trust that analog reading. |
| Likely DIY time | The cited steps give no time. With power locked out, check that the connector is plugged in and undamaged and look for chafed or pinched wiring, then one reset. |
| Typical parts | The transducer or probe on the named input, or its wiring. No part number in the entry. The correct replacement is a technician's call if the fault returns. |
| Urgency | Stop. Lock power out before you touch the sensor connector. |
What the controller is measuring
A device on the indicated analog input (pressure transducer, temperature probe, etc.) or its wiring has failed — HIGH indicates an open circuit, LOW a short. The compressor shuts down because the controller can no longer trust that reading.
HIGH means the indicated analog input is open. LOW means it is shorted. The device on that input is a pressure transducer, a temperature probe, or another analog sensor, or the wiring to it. The compressor shuts down because the controller can no longer trust the reading. This is not the high-temperature trip. High Temperature 1, 2, or 3 is the message for a real temperature above its set limit. The blank in the fault name is the input the display is naming.
What causes it?
- Open circuit (HIGH) or short (LOW) in the named analog sensor or its wiringHow to confirm: With power locked out, look at the connector for the named input. It should be plugged in and undamaged. HIGH is the open-circuit reading and LOW is the short.
- A failed transducer or temperature probeHow to confirm: Look for chafed or pinched wiring on that same circuit. This step is visual. The entry says a meter test belongs to the technician if the fault returns.
- A momentary loose connectionHow to confirm: Reset and restart once. If the fault stays gone, the documented cause is a momentary loose connection. If it returns, the transducer or probe needs testing.
Step by step
Sometimes — with power locked out, check the connector and look for chafed wiring, then reset once.
- With power locked out, visually check that the sensor connector is plugged in and undamaged
- Look for chafed or pinched sensor wiringSafety: power stays locked out while you look at the wiring.
- Reset and restart once to rule out a momentary connection issue
Parts and consumables
What the verified entry already names. OEM catalog numbers are not in that entry, so none are added here.
- The sensor on the named analog input — a pressure transducer or a temperature probe. The entry says to use the correct replacement part and gives no part number.
- The connector and the wiring to that sensor — the visual check with power locked out.
When to call a technician
If it returns, the transducer or probe needs meter testing and the correct replacement part — sensor diagnosis, not parts-cannon guessing.
- The fault returns after the connector and the wiring look intact and the compressor has been reset once.
- The next step is a meter test of the transducer or probe. The guidance says that is a technician's job.
- The replacement part is being guessed. The entry says the correct replacement part, and it does not list a number.
Which controller shows this?
Same 10-inch Sullair Touch Screen as the named temperature faults. This message is a failed analog input, not a process limit. Warnings on the STS leave the machine running. This one is a fault, so the compressor stays down until it is reset, and it will come straight back if the input is still open or shorted. Sullair Touch Screen (STS) code list.
More questions
Does HIGH AN_ SENSOR mean the temperature is high?
No. HIGH means an open circuit on the indicated analog input. LOW means a short. The high-temperature shutdown is a different STS message, High Temperature 1, 2, or 3. This fault means the controller no longer trusts the reading from that device, which the entry names as a pressure transducer, a temperature probe, or the wiring to it.
The display names a channel after AN. Where is the pinout?
It is not in this entry. The blank in HIGH AN_ SENSOR / LOW AN_ SENSOR is the indicated analog input, and the name on the screen is the one to write down. This directory does not list a pinout or a part number for those inputs. The cited check is visual, with power locked out: connector seated and undamaged, wiring not chafed or pinched, then one reset.
Can any probe of the same thread size replace it?
The cited guidance does not say that. If the fault returns, a technician tests the transducer or probe and fits the correct replacement part. The entry says the diagnosis needs a meter, and it does not give a part number. This page does not name a substitute.
Verified against service documentation: Sullair Touch Screen (STS) documentation for HIGH AN_ SENSOR / LOW AN_ SENSOR (sullair.com). Last reviewed November 5, 2026.