❄ Compressor Code Lookup
Home › Gardner Denver › SHUTDOWN #122 HIGH PKG DISCH TMP
Gardner Denver AirSmart controller · SHUTDOWN #122 HIGH PKG DISCH TMP

Gardner Denver shutdown 122: why is package discharge air too hot?

Short answer: High package discharge (plant air) temperature. If your Gardner Denver AirSmart controller is showing SHUTDOWN #122 HIGH PKG DISCH TMP, the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

Air leaving the package exceeded 158°F (70°C), indicating the aftercooler is not removing enough heat.

Which machines show this?

Gardner Denver rotary screw compressors fitted with the first-generation AirSmart microprocessor controller — a wide range of oil-injected packages, including VFD-equipped variable-speed units where the controller supervises the drive. The first-generation AirSmart reports problems as numbered codes: SHUTDOWN #1xx and #2xx faults that stop the machine, and ADVISORY #3xx warnings that let it keep running while flagging maintenance. That numbering matters when you search — the later AirSmart G2 dropped the numbers and displays plain-text fault names instead, so a numbered code on the screen tells you that you are on the earlier controller. Shutdowns clear with Stop/Reset once the machine has stopped; advisories acknowledge with the Enter key.

What causes it?

  • Aftercooler faces blinded with dust so heat isn't leaving the package air
  • Hot compressor room or poor ventilation raising the cooling air temperature
  • The machine running flat out in conditions the aftercooler can't keep up with
  • Internal aftercooler fouling that surface cleaning won't reach (the repeat case)

Can you fix it yourself?

Usually, yes — clean the cooler faces with the machine off, improve ventilation, and ease the load. If plant air still leaves hotter than 158°F after that, the cooler needs service.

Step by step — what to try, in order:

  1. Improve room ventilation and lower ambient temperature if possible
  2. With the machine off and cooled, clean dust and debris from the cooler faces
  3. Reduce load on the compressor if it has been running flat out
  4. Press Stop/Reset and restart while monitoring the plant temperature reading
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

Internal cooler fouling can't be cleared from outside; it takes partial teardown of the cooling circuit, and confirming it requires temperature measurements across the cooler that need proper instruments.

When to call: Call a technician if temperatures stay high after cleaning and ventilation fixes — internal cooler fouling requires service.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does SHUTDOWN #122 HIGH PKG DISCH TMP mean on a Gardner Denver AirSmart controller?

High package discharge (plant air) temperature. Air leaving the package exceeded 158°F (70°C), indicating the aftercooler is not removing enough heat.

Can I fix SHUTDOWN #122 HIGH PKG DISCH TMP on a Gardner Denver AirSmart controller myself?

Usually, yes — clean the cooler faces with the machine off, improve ventilation, and ease the load. If plant air still leaves hotter than 158°F after that, the cooler needs service.

When does SHUTDOWN #122 HIGH PKG DISCH TMP on a Gardner Denver AirSmart controller need a technician?

Internal cooler fouling can't be cleared from outside; it takes partial teardown of the cooling circuit, and confirming it requires temperature measurements across the cooler that need proper instruments. Call a technician if temperatures stay high after cleaning and ventilation fixes — internal cooler fouling requires service.

Verified against service documentation: Gardner Denver AirSmart controller documentation for SHUTDOWN #122 HIGH PKG DISCH TMP (best-aire.com)

Other Gardner Denver AirSmart controller codes