Sullair ShopTek Controller · HIGH PRESSURE

Why did my Sullair ShopTek compressor trip on high pressure?

Short answer: Operating pressure above shutdown limit. If your Sullair ShopTek Controller is showing HIGH PRESSURE, the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

The compressor operating pressure exceeded the set shutdown limit — caused by a faulty pressure sensor, a control/valve problem, or a faulty unload solenoid valve.

Which machines show this?

Sullair's ShopTek line of smaller shop-duty rotary screw compressors — the ST-series packages aimed at garages, tire shops, and light manufacturing — with the compact ShopTek controller. Its display is terse: faults appear as short all-caps messages such as HIGH DISCH TEMP, PR XDCR FAULT, RTD FAULT, and A-O SEPARATOR, mixing hard shutdowns with service reminders in the same format. Discharge temperature warns above 225 °F and shuts down at the set limit. Practical tip: on these units learn which messages are reminders (A-O SEPARATOR is a service interval, not a failure) and which are trips — resetting a reminder without doing the service just deletes your warning, not the problem.

What causes it?

  • Faulty pressure sensor
  • A control or valve problem keeping the unit loaded
  • Faulty unload solenoid valve

Can you fix it yourself?

Partly — blow down, confirm setpoints match the machine's rating, restart once, and watch whether it unloads at target.

Step by step — what to try, in order:

  1. Stop the unit and let it blow down
  2. Confirm the pressure setpoints match the machine's rating
  3. Restart once and watch whether the unit unloads at the target pressure
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

A recurring trip needs the unload solenoid, control valves, and pressure sensor checked by service — overpressure events are not to be reset repeatedly.

When to call: Call service to check the unload solenoid, control valves, and pressure sensor if the trip recurs.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does HIGH PRESSURE mean on a Sullair ShopTek Controller?

Operating pressure above shutdown limit. The compressor operating pressure exceeded the set shutdown limit — caused by a faulty pressure sensor, a control/valve problem, or a faulty unload solenoid valve.

Can I fix HIGH PRESSURE on a Sullair ShopTek Controller myself?

Partly — blow down, confirm setpoints match the machine's rating, restart once, and watch whether it unloads at target.

When does HIGH PRESSURE on a Sullair ShopTek Controller need a technician?

A recurring trip needs the unload solenoid, control valves, and pressure sensor checked by service — overpressure events are not to be reset repeatedly. Call service to check the unload solenoid, control valves, and pressure sensor if the trip recurs.

Verified against service documentation: Sullair ShopTek Controller documentation for HIGH PRESSURE (best-aire.com)