Sullair ShopTek Controller · RTD FAULT

What does RTD FAULT mean on a Sullair compressor?

Short answer: Temperature sensor (RTD) fault. If your Sullair ShopTek Controller is showing RTD FAULT, the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

The temperature sensor has failed or its connection has come loose; the machine stops because discharge temperature can no longer be monitored.

Which machines show this?

Sullair's ShopTek line of smaller shop-duty rotary screw compressors — the ST-series packages aimed at garages, tire shops, and light manufacturing — with the compact ShopTek controller. Its display is terse: faults appear as short all-caps messages such as HIGH DISCH TEMP, PR XDCR FAULT, RTD FAULT, and A-O SEPARATOR, mixing hard shutdowns with service reminders in the same format. Discharge temperature warns above 225 °F and shuts down at the set limit. Practical tip: on these units learn which messages are reminders (A-O SEPARATOR is a service interval, not a failure) and which are trips — resetting a reminder without doing the service just deletes your warning, not the problem.

What causes it?

  • Temperature sensor (RTD) failed
  • Sensor connection loose or wiring damaged

Can you fix it yourself?

Sometimes — check the connector and visible wiring with power locked out, then one restart.

Step by step — what to try, in order:

  1. With power locked out, check the sensor connector and visible wiring for damage
  2. Reset and attempt one restart
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

If the fault persists, the RTD must be replaced before the machine runs — operating without discharge-temperature protection is how airends die.

When to call: Call a technician to replace the RTD if the fault persists — running without temperature protection is not safe.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does RTD FAULT mean on a Sullair ShopTek Controller?

Temperature sensor (RTD) fault. The temperature sensor has failed or its connection has come loose; the machine stops because discharge temperature can no longer be monitored.

Can I fix RTD FAULT on a Sullair ShopTek Controller myself?

Sometimes — check the connector and visible wiring with power locked out, then one restart.

When does RTD FAULT on a Sullair ShopTek Controller need a technician?

If the fault persists, the RTD must be replaced before the machine runs — operating without discharge-temperature protection is how airends die. Call a technician to replace the RTD if the fault persists — running without temperature protection is not safe.

Verified against service documentation: Sullair ShopTek Controller documentation for RTD FAULT (best-aire.com)