Why does my Sullair ShopTek compressor trip on motor overload?
Short answer: Drive motor overload trip. If your Sullair ShopTek Controller is showing MOTOR OVERLOAD, the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.
What exactly is the machine telling you?
The motor overload relay tripped due to a power overload in the motor — low line voltage, incorrect configuration, or load pressure set above the compressor's limit are documented causes.
Which machines show this?
Sullair's ShopTek line of smaller shop-duty rotary screw compressors — the ST-series packages aimed at garages, tire shops, and light manufacturing — with the compact ShopTek controller. Its display is terse: faults appear as short all-caps messages such as HIGH DISCH TEMP, PR XDCR FAULT, RTD FAULT, and A-O SEPARATOR, mixing hard shutdowns with service reminders in the same format. Discharge temperature warns above 225 °F and shuts down at the set limit. Practical tip: on these units learn which messages are reminders (A-O SEPARATOR is a service interval, not a failure) and which are trips — resetting a reminder without doing the service just deletes your warning, not the problem.
What causes it?
- Low line voltage into the motor
- Load pressure set above the compressor's limit
- Incorrect machine configuration
Can you fix it yourself?
Partly — cool-down, one reset, verifying the load pressure setting, and flagging low building voltage to the power company.
Step by step — what to try, in order:
- Let the overload element cool, then reset
- Verify load pressure is set below the compressor's limit
- If building voltage is low, consult the power company
When do you need a technician — and why?
Motor amps, starter contacts, and connections need checking with instruments in a line-voltage enclosure — electrician or service tech on a repeat trip.
If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.
Related questions
What does MOTOR OVERLOAD mean on a Sullair ShopTek Controller?
Drive motor overload trip. The motor overload relay tripped due to a power overload in the motor — low line voltage, incorrect configuration, or load pressure set above the compressor's limit are documented causes.
Can I fix MOTOR OVERLOAD on a Sullair ShopTek Controller myself?
Partly — cool-down, one reset, verifying the load pressure setting, and flagging low building voltage to the power company.
When does MOTOR OVERLOAD on a Sullair ShopTek Controller need a technician?
Motor amps, starter contacts, and connections need checking with instruments in a line-voltage enclosure — electrician or service tech on a repeat trip. Call an electrician or service tech to check motor amps, starter contacts, and connections if it trips again.
Verified against service documentation: Sullair ShopTek Controller documentation for MOTOR OVERLOAD (best-aire.com)