Sullair ShopTek Controller · PR XDCR FAULT

What does PR XDCR FAULT mean on a Sullair compressor?

Short answer: Pressure transducer fault. If your Sullair ShopTek Controller is showing PR XDCR FAULT, the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

The pressure transducer has failed or a connection has come loose, and the compressor shuts down because the controller cannot read system pressure.

Which machines show this?

Sullair's ShopTek line of smaller shop-duty rotary screw compressors — the ST-series packages aimed at garages, tire shops, and light manufacturing — with the compact ShopTek controller. Its display is terse: faults appear as short all-caps messages such as HIGH DISCH TEMP, PR XDCR FAULT, RTD FAULT, and A-O SEPARATOR, mixing hard shutdowns with service reminders in the same format. Discharge temperature warns above 225 °F and shuts down at the set limit. Practical tip: on these units learn which messages are reminders (A-O SEPARATOR is a service interval, not a failure) and which are trips — resetting a reminder without doing the service just deletes your warning, not the problem.

What causes it?

  • Pressure transducer failed
  • A connection come loose — sometimes just a momentary one

Can you fix it yourself?

Sometimes — a locked-out look at the transducer connector and one reset covers the loose-plug case.

Step by step — what to try, in order:

  1. With power locked out, visually check the transducer connector for looseness or damage
  2. Reset and restart once to rule out a momentary loose connection
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

A returning fault needs the transducer tested and replaced — the compressor shuts down because the controller cannot read system pressure at all.

When to call: Call service to test and replace the pressure transducer if the fault returns.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does PR XDCR FAULT mean on a Sullair ShopTek Controller?

Pressure transducer fault. The pressure transducer has failed or a connection has come loose, and the compressor shuts down because the controller cannot read system pressure.

Can I fix PR XDCR FAULT on a Sullair ShopTek Controller myself?

Sometimes — a locked-out look at the transducer connector and one reset covers the loose-plug case.

When does PR XDCR FAULT on a Sullair ShopTek Controller need a technician?

A returning fault needs the transducer tested and replaced — the compressor shuts down because the controller cannot read system pressure at all. Call service to test and replace the pressure transducer if the fault returns.

Verified against service documentation: Sullair ShopTek Controller documentation for PR XDCR FAULT (best-aire.com)