Sullair WS Controller · Aux Motor Overload

What does Aux Motor Overload mean on a Sullair WS controller?

Short answer: Auxiliary motor (fan/pump) overload trip. If your Sullair WS Controller is showing Aux Motor Overload, the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

The auxiliary motor overload relay tripped on the cooling fan, fluid pump, or other auxiliary motor.

Which machines show this?

Sullair's mid-range stationary rotary screws fitted with the WS controller — a text-display unit found on many shop and light-industrial packages from the 2010s. The WS names its faults in plain English (High Temperature, Separator dP High, Aux Motor Overload, Power Interruption) and uses staged temperature protection: a warning at 225 °F, a time-delayed fault at 235 °F, and an immediate trip at 255 °F. Faults are reset from the STOP key after the cause is corrected and the unit has cooled. Practical tip: if the auto-restart timer is configured, the machine can start by itself after a power interruption — make sure nobody is working near it before you walk away from a Power Interruption message.

What causes it?

  • Cooling fan or fluid pump motor drawing excess current
  • Fan blocked by debris (check with power locked out)
  • Building voltage sagging — dimming lights are the tell

Can you fix it yourself?

Sometimes — cool-down, a locked-out check that the fan spins freely, and one reset. Repeated trips end the DIY phase.

Step by step — what to try, in order:

  1. Allow the overload element to cool before resetting
  2. Check that the cooling fan spins freely and is not blocked by debris (power locked out)
  3. If lights dim or voltage sags in the building, have the utility supply checked
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

Verifying motor amps, starter contacts, and connections is instrument work in a live-capable enclosure — electrician or service tech.

When to call: Call an electrician or service tech to verify motor amps, starter contacts, and connections if it trips again.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does Aux Motor Overload mean on a Sullair WS Controller?

Auxiliary motor (fan/pump) overload trip. The auxiliary motor overload relay tripped on the cooling fan, fluid pump, or other auxiliary motor.

Can I fix Aux Motor Overload on a Sullair WS Controller myself?

Sometimes — cool-down, a locked-out check that the fan spins freely, and one reset. Repeated trips end the DIY phase.

When does Aux Motor Overload on a Sullair WS Controller need a technician?

Verifying motor amps, starter contacts, and connections is instrument work in a live-capable enclosure — electrician or service tech. Call an electrician or service tech to verify motor amps, starter contacts, and connections if it trips again.

Verified against service documentation: Sullair WS Controller documentation for Aux Motor Overload (best-aire.com)