❄ Compressor Code Lookup
Home › Sullair › Separator dP High
Sullair WS Controller · Separator dP High

Why is separator pressure drop high on my Sullair WS compressor?

Short answer: Separator pressure differential trip. If your Sullair WS Controller is showing Separator dP High, the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

The pressure differential across the air/fluid separator has exceeded the set high limit (warning threshold is 10 psid). Plugged separator elements or a pressure sensor failure are the documented causes.

Which machines show this?

Sullair's mid-range stationary rotary screws fitted with the WS controller — a text-display unit found on many shop and light-industrial packages from the 2010s. The WS names its faults in plain English (High Temperature, Separator dP High, Aux Motor Overload, Power Interruption) and uses staged temperature protection: a warning at 225 °F, a time-delayed fault at 235 °F, and an immediate trip at 255 °F. Faults are reset from the STOP key after the cause is corrected and the unit has cooled. Practical tip: if the auto-restart timer is configured, the machine can start by itself after a power interruption — make sure nobody is working near it before you walk away from a Power Interruption message.

What causes it?

  • Separator elements plugged (warning threshold is 10 psid)
  • Pressure sensor failure — the other documented cause

Can you fix it yourself?

The homework is in-house: check separator hours against the schedule and arrange the replacement. The swap itself is not.

Step by step — what to try, in order:

  1. Check separator hours against the maintenance schedule
  2. Arrange replacement of the separator element
  3. Visually check sensor wiring connections with power locked out
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

The separator lives inside the pressurized sump vessel, so the element change goes to a technician.

When to call: Call a technician to replace the separator — it is inside the pressurized sump vessel.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does Separator dP High mean on a Sullair WS Controller?

Separator pressure differential trip. The pressure differential across the air/fluid separator has exceeded the set high limit (warning threshold is 10 psid). Plugged separator elements or a pressure sensor failure are the documented causes.

Can I fix Separator dP High on a Sullair WS Controller myself?

The homework is in-house: check separator hours against the schedule and arrange the replacement. The swap itself is not.

When does Separator dP High on a Sullair WS Controller need a technician?

The separator lives inside the pressurized sump vessel, so the element change goes to a technician. Call a technician to replace the separator — it is inside the pressurized sump vessel.

Verified against service documentation: Sullair WS Controller documentation for Separator dP High (best-aire.com)

Other Sullair WS Controller codes