❄ Compressor Code Lookup
Home › Sullair › E-Stop Push Button
Sullair WS Controller · E-Stop Push Button

How do I clear an E-Stop fault on a Sullair WS controller?

Short answer: Emergency stop activated. If your Sullair WS Controller is showing E-Stop Push Button, the controller has logged a specific, documented condition. This page covers what it means, what causes it, what you can safely fix yourself, and when — and why — it takes a technician.

What exactly is the machine telling you?

The emergency stop button has been pressed, or the button/wiring is faulty, shutting the compressor down.

Which machines show this?

Sullair's mid-range stationary rotary screws fitted with the WS controller — a text-display unit found on many shop and light-industrial packages from the 2010s. The WS names its faults in plain English (High Temperature, Separator dP High, Aux Motor Overload, Power Interruption) and uses staged temperature protection: a warning at 225 °F, a time-delayed fault at 235 °F, and an immediate trip at 255 °F. Faults are reset from the STOP key after the cause is corrected and the unit has cooled. Practical tip: if the auto-restart timer is configured, the machine can start by itself after a power interruption — make sure nobody is working near it before you walk away from a Power Interruption message.

What causes it?

  • The E-stop button pressed — find out why before touching anything
  • A faulty button or wiring holding the fault active

Can you fix it yourself?

Yes — confirm the reason, release the button, and restart per normal procedure. That covers nearly every case.

Step by step — what to try, in order:

  1. Confirm why the E-stop was pressed before resetting anything
  2. Twist/pull the E-stop button to release it
  3. Restart the compressor per normal procedure
One reset is diagnosis, repeated resets are damage. If the same fault returns after a single reset, the underlying condition is real — stop resetting and deal with the cause.

When do you need a technician — and why?

A fault that stays active with the button released means the button or its wiring is faulty — safety-circuit repair for service.

When to call: Call service if the fault stays active with the button released — the button or its wiring is faulty.

If it does come to a service call and you're in Nashville, TN or Birmingham, AL, we maintain independently compiled lists of local companies that service industrial air compressors — real businesses with verified contact information, none of whom paid to be listed.

Related questions

What does E-Stop Push Button mean on a Sullair WS Controller?

Emergency stop activated. The emergency stop button has been pressed, or the button/wiring is faulty, shutting the compressor down.

Can I fix E-Stop Push Button on a Sullair WS Controller myself?

Yes — confirm the reason, release the button, and restart per normal procedure. That covers nearly every case.

When does E-Stop Push Button on a Sullair WS Controller need a technician?

A fault that stays active with the button released means the button or its wiring is faulty — safety-circuit repair for service. Call service if the fault stays active with the button released — the button or its wiring is faulty.

Verified against service documentation: Sullair WS Controller documentation for E-Stop Push Button (best-aire.com)

Other Sullair WS Controller codes